- 5 -
1.2.
Dsub 9P male (P1)
number name
description
level
Dir.
Etc.
1
-
-
-
-
-
2
RXD
Receive Data
RS232
Input Mandatory
3
TXD
Transmit Data
RS232 Output Mandatory
4
DTR Data Terminal Ready
-
-
Optional
5
GND
Ground
Ground
-
Mandatory
6
DSR
Data Set Ready
-
-
Optional
7
RTS
Request To Send
RS232 Output
Optional
8
CTS
Clear To Send
RS232
Input
Optional
9
-
-
-
-
-
DTR and DSR can be loop backed with a DTR/DSR loopback jumper (JP6).
See the below section for more information.
1.3.
DTR/DSR loopback jumper (JP6)
Some devices require DSR signal (DTR in terms of EZL-90). The devices
recognize the counterpart serial device with DSR. To get DSR signal from
the counterpart serial device, the counterpart serial devices have to
signal DTR.
EZL-90 has no DTR signal, but it has DTR/DSR loopback jumper. If user
set the jumper, EZL-90 returns its DSR signal from user device to DTR
so that user device recognizes the EZL-90.
1.4.
Alternative Connector (JP8)