5. Operation
5. 6 . 6 .5 Battery Wakeu p
This function should be activated only after the installation. In the case of a low battery
voltage shutdown , the inverter will shut-down. This setting can be enabled , so when the
inverter detects PV or grid it wakes up the battery. This function conflicts with the battery
reverse polarity protection ( If the installer connects cables with wrong polarity, the inverter
can protect itself from damage).To avoid the possible damage during installation, do not
active battery wakeup function before finishing the first commissioning.
5. 6 . 7 Export power Set
.46.
This function is to set the export power control.
1 . Backflow Power. 2. ON/OFF. 3.Fai lsafe ON/OFF
Setting 1 &3 are only valid when Setting 2 is set to " O N"
Export power Set
201 5-02-23 1 9 35
:
:
..
.
.
.
-
ON/OFF
Fa1ISafe ON/OFF
Figure 5.44 Export power Set
5. Operation
5. 6 . 7 . 1 Backflow Power
Determine the allowed backfeed power. (System export to the grid)
Backflow Power
201 5-02-23 1 9 35
Backflow Power :
dt..t,tnt/1
5. 6 . 7 .2 ON/O F F
Enable/Disable the function .
Y E S = < E N T > N O = < E S C >
Figure 5.45 Backflow Power
ON/OFF
201 5-02-23 1 9 35
•
Y E S = < E N T > N O = < E S C >
Figure 5.46 O N/OFF
.47.