50
User Manual
MHS-3~8K
series
Cable requirements
Cable stripping length
Outside diameter
Conductor core section
5.0-8.0 mm
10 mm²
10 mm
10mm
Figure 5-37
If the conductor core of the battery cable is too small, which may cause
poor contact between the terminal and the cable, please use the cable
specified in the above table, or contact Solinteg to purchase terminals
of other specifications.
CAUTION
①
Peel off the battery cable insulation sleeve for 10 mm.
※ 5.7 Power Cable of the Battery Connection
Please contact your battery supplier for detailed battery installation
information.
NOTE
5.7.1 The following principles must be considered when making battery connection:
①
Disconnect the AC breaker on the grid side.
②
Disconnect the breaker on the battery side.
③
Turn the inverter DC switch to the “OFF” position.
④
Make sure the maximum input voltage of battery is within the inverter limitation.
5.7.2 Lithium battery connector assembly procedures
Select an appropriate DC cable
②
Disassemble the connector in the accessory bag.