Solight TE81 User Manual Download Page 2

 

Temperature in °C or °F  

 

3-digit room temperature display. Measurement Accuracy: +/– 1°C, measurement range 0°C + 50°C  

 

2-digit room and outside humidity display. Measurement Accuracy: +/- 5%, measurement range 20% - 95% 

 

3-digit outside temperature display. Measurement Accuracy: +/– 1°C, measurement range -20°C + 60°C  

 

When an alarm goes off or when the device is in RCC signal reception mode (Radio Clock Control Signal), the device stops measuring temperature.  

 

The high frequency receiver is capable of receiving data from up to three channels (transmitters)  

 

Memory for storing maximum and minimum inside and outside temperature and humidity   

 

Main unit and outdoor transmitter battery depletion indication on the display using the              symbol 

 

Units for air pressure measurement: mb/hPa, inHg  

 

Alarm clock 

 

Temperature alarm for outside temperature 

 

5V USB output, supply power 1200 mA  

 

Snooze function (5 minutes) 

 

Daylight Saving Time (DST) 

 

Moon phase indication 

 

Environmental comfort function 

 

Icing indication the       symbol (for temperatures between –1°C and +3°C) 

 

The device operates at a frequency of 433.92 MHz 

 

3.

 

DEVICE FEATURES AND OPERATION 

3.1

 

   Setting Time 

In standard mode, press the         button for at least 2 seconds to get to the time setting mode. The active segment starts blinking. 
Setting sequence: 12/24Hr → time zone shift → hours → minutes → date format DD/MM or MM/DD → year → MM/DD or DD/MM date setting (according to 
the date format) → days of the week language (GE, FR, SP, IT, DU, DA, EN). Setting the values can be exited by pressing the          button, resulting in the 
segments stopping to blink.  Pressing the          or            button brings you one step forward or backward; holding the buttons allows for quicker progression. 

 

3.2

 

   Setting the Alarm Clock  

In standard mode, press the        button, the time display section shows the set alarm time. In standard mode, press the          button for at least 2 seconds to go 
to the alarm clock setting mode, the main segment starts blinking. Setting sequence: hour → minute → exit. Pressing the         or           button brings you one 
step forward or backward; holding the buttons allows for quicker progression. The snooze value is permanently set to 5 minutes. Setting the values can be 
ended by moving through the menu, using the            button, until the set segments stop blinking. Unless a button is pressed within 20 seconds, the device leaves 
the setting mode and stores the currently set alarm time. If you want to turn off the alarm completely, move the alarm switch it to the off position.  
 
3.3

 

Alarm Settings 

Turning the alarm on or off is done using the on/off switch               . When the alarm goes off, a ZZ symbol starts blinking on the display. If you press                      

        / ZZ when the alarm is sounding, the alarm will be postponed by 5 minutes. Pressing any other button turns the alarm off. Using the snooze function, an 
alarm may be postponed indefinitely. When the alarm is sounding, the RCC signal is not being received. Reception resumes after the alarm is turned off. After 
two minutes, the alarm is shut off automatically. The progression of the alarm sound is as follows:  a) 0-10 seconds: one beep per second, b) 10 – 20 seconds two 
beeps per second, c) after 20 seconds – three beeps per second. 
 
3.4

 

 Sensor Toggle Function 

 
In standard mode, pressing the          button will toggle channels (CH1, CH2, CH3 or the option of cycling through all three channels). When cycling is on, the 
display shows the 

 symbol. In the cyclical three channel display mode the values change on their own. In the cyclical mode, when fewer than three outdoor 

sensors are connected, the channels with no sensors connected will show no data. 
 
3.5

 

Sensor Pairing Function 

 
First, separate channels must be selected on the individual sensors. Open the battery compartment cover and move the position switch to the desired channel 
number 1, 2, or 3. Reinsert the batteries and close the cover. When powering up for the first time, an automatic sensor pairing is conducted. If, however, you 
want to change the pairing, change the channel by pressing the              button and hold it for at least two seconds. The pairing process takes approximately three 
minutes. If the pairing process is unsuccessful, the weather station is probably out of signal range. 
 
3.6

 

Temperature Alarm Settings Functions  

 
A temperature alarm can be set at the outdoor sensor side only.

 

To access the temperature alarm settings mode, hold the

        

button for at least 2 seconds. 

First, the part of the display for setting the max. alarm temperature starts blinking. Using the        or         buttons, set the maximum temperature alarm value. By 
briefly pressing the            button, move on to setting the minimum alarm temperature. Using the          or          buttons set the minimum temperature alarm 
value. Another brief pressing of the            button will exit the temperature alarm settings mode. The range for the temperature alarm is from –20 °C to 60 °C. 
The temperature alarm is activated by briefly pressing the           button, what is indicated by the ALERTS notification being displayed: 
  
 
When the minimum or maximum set temperature is exceeded, an alarm sounds, the value of the temperature exceeded starts blinking and a            or          
symbol is displayed. The alarm will sound for 5 seconds, unless it is shut off by pressing any button. If the sound alarm is terminated, but the temperature alarm 
is not deactivated, the value of the temperature exceeding the preset range will keep blinking. The temperature alarm can be disabled by briefly pressing the       
button. If the alarm is not disabled, it will be reactivated every minute, as long as the temperature stays outside of the preset range. 

 

3.7

 

RCC Control Signal Reception 

 

 

RCC signal reception is activated automatically upon powering up or resetting. 

 

Forced RCC signal reception: press the         button.  

 

Once signal reception is activated, a three-minute synchronization period commences. While the synchronization is in progress, it is not possible to access 
any functions and the weather station is not taking any measurements, The charging USB output is also deactivated.  

 

Daily automatic signal reception. 