background image

Numerous reported cases of carbon monoxide poisoning indicate that victims realize their sickness 
but are so disoriented that they are unable to rescue themselves, i.e. to leave the building or call for 
help. Small children and pets are usually the first affected ones. Exposure during sleep is particularly 
dangerous because the victim usually does not wake up. 

Detector location  

Since  carbon  monoxide  moves  freely  in  air,  the 
detector  should  be  placed  in  areas  where  people 
sleep or in their direct vicinity. The human body is 
most  sensitive  to  the  effects  of  CO  while  asleep. 
For  maximum  protection,  the  detector  should  be 
placed close to the area intended for sleeping or on 
every  floor  of  your  house.  The  diagram  below 
indicates  some  recommended  places  inside  the 
house.  The  electronic  sensor  detects  carbon 
monoxide, measures its concentration and triggers 
a  loud  audible  alarm  before  a  potentially  harmful 
concentration is achieved. 

We recommend you to mount the detector onto the wall and to the ceiling, see pictures below. 

 

Wall mounting 

 

 

 

        Ceiling mounting 

 

 

 

 

Do not install the detector: 

a)  to places where temperature may drop below -
10⁰C (14⁰F) or exceed 40⁰C (104⁰F) 

b)  to places with possible occurrence of solvent vapours and with high humidity 
c)  within 1.5 metres away from sources of open flame such as ovens, stoves or fireplaces 
d)  into gas engine exhaust pipes, into air ducts, smoke ducts or chimneys  
e)  close to car exhaust pipe; this would destroy the detector. 

Product specification 

Power supply: 

 

2x AAA 1.5V alkaline batteries (LR6) 

Sensor type:  

            

Electro-chemical 

Alarm activation (sensitivity):  30 

– 49ppm (120 minutes) 

 

 

            

50 

– 99ppm (60 – 90 minutes) 

 

 

            

100 

– 299ppm (10 – 40 minutes) 

 

 

            

above 300ppm (0 

– 180 seconds) 

Operating temperature:  

-

10°C to +40°C 

Operating humidity:  

15 

– 90% 

Max. sound level:              

85dB within 1m range 

Dimensions:  

            

Ø 68mm x 35mm; weight: approx. 60g (without batteries) 

Detector mounting 

1.  Release rear cover by turning it anti-clockwise. 

Bedroom 

Bedroom 

Bedroom 

Living room 

Kitchen 

Cellar 

Garage 

≥185cm 

≥150cm 
above floor 

61cm 

Reviews: