C. Clearance 

When placing the repeater, it requires the minimum space to keep distance from another.   

 

 

 

 

Summary of Contents for RocketWAVE SRF-L-8A1821

Page 1: ...RocketWAVE SRF L 8A1821 Product Manual DEC 2021 V1 7 ...

Page 2: ... respect to such trademark Other product names mentioned in this manual are used for identification purposes only and may be trademarks or registered trademarks of their respective companies Disclaimer of Liability The contents of this document including graphics and screenshots are current as of the date of publication SOLiD reserves the right to change the contents without prior notice In no eve...

Page 3: ...rview 7 Service Frequency Bandwidth 7 In Output Power Gain 7 800MHz Adaptive band combinations 8 2 2 Functions 8 Repeater Interface 12 Package Configuration 13 Installation 14 5 1 Donor antenna installation 14 5 2 Repeater installation 14 5 3 USIM Installation 17 Software 18 6 1 LMT DT_GUI Installation 18 6 2 LMT User Interface 19 6 3 Firmware Upgrade 21 Appendix 22 7 1 General specification 22 7 ...

Page 4: ...ions or fit any spare parts which are not sold or recommended by the manufacturer This could cause fires electric shock or other injuries Any repeater including this repeater will generate radio signals and thereby give rise to electromagnetic fields that may be hazardous to the health of any person who is extensively exposed to the signals at the immediate proximity of the repeater and the repeat...

Page 5: ...2 2010 FAST TRANSIENT IMMUNITY IEC61000 4 4 2004 SURGE IMMUNITY IEC61000 4 5 2005 CONDUCTED DISTURBANCES IMMUNITY IEC61000 4 6 2008 VOLTAGE DIPS INTERRUPTION VARIATIONS IEC61000 4 11 2004 The installation to comply with European EN50385 exposure compliance requirements the following Power Density limits guidelines mW cm2 according to ICNIRP are valid 0 2 for frequencies from 10 MHz to 400 MHz F MH...

Page 6: ...owing website https solid com emea resources product literature WEEE Recycling SOLiD complies with collection and recycling arrangements per the Waste Electrical and Electronic Equipment WEEE Directive and implementing regulations See more information at https solid com emea resources product literature For all technical support or product return requests please ensure you have the SOLiD product i...

Page 7: ...device comes with various embedded function and feature for the stable and sustainable O M The LTE modem is embedded in the device that support NMS by communicating through LTE signal System operation can be monitored by carrier NMS in NoC And through this NMS feature the device S W can be easily upgraded and fix when there is a case Implementing with this features user is able to experience the s...

Page 8: ...811 MHz 847 MHz 849 5 MHz 852 MHz 811 MHz 813 5 MHz 816 MHz 852 MHz 854 5 MHz 857 MHz 816 MHz 818 5 MHz 821 MHz 857 MHz 859 5 MHz 862 MHz 10 MHz 791 MHz 796 MHz 801 MHz 832 MHz 837 MHz 842 MHz 796 MHz 801 MHz 806 MHz 837 MHz 842 MHz 847 MHz 801 MHz 806 MHz 811 MHz 842 MHz 847 MHz 852 MHz 806 MHz 811 MHz 816 MHz 847 MHz 852 MHz 857 MHz 811 MHz 816 MHz 821 MHz 852 MHz 857 MHz 862 MHz The following b...

Page 9: ...time and set the gain value again Once the repeater starts to operate the system performs the Isolation Check process one more time once a day During the Isolation Recheck the repeater is not going to shut down If the isolation oscillation occurs while the repeater is operating in the minimum gain value Over output Shutdown function performs to protect the repeater and this time the gain value is ...

Page 10: ...3 dBm 64 dB 64 dB 46 dBm 13 dBm 59 dB 59 dB 41 dBm 13 dBm 54 dB 54 dB 36 dBm 13 dBm 49 dB 49 dB 31 dBm 13 dBm 44 dB 44 dB 26 dBm 13 dBm 39 dB 39 dB 21 dBm 13 dBm 34 dB 34 dB Auto Level Control ALC for UL over input This function is that preventing and maintaining the signal quality degradation due to UL s over input power satu ration The attenuator is located after UL Low Noise Amplifier LNA The U...

Page 11: ...rvice band when the DL UL output of each service band is over the rated During DL Shutdown UL Shutdown is also proceed at the same time and this is vice versa The operating level is Rated output level 2dB 2dB and working algorithm is described as follows In Check state if the power level is back to normal from over output level the algorithm is reset If Complete Shutdown occurs a repeater is kept ...

Page 12: ...SOLiD RocketWAVE SRF L 8A1821 Product Manual V1 7 DEC 2021 2021 SOLiD Inc All Rights Reserved Confidential Proprietary Page 12 Repeater Interface ...

Page 13: ...SOLiD RocketWAVE SRF L 8A1821 Product Manual V1 7 DEC 2021 2021 SOLiD Inc All Rights Reserved Confidential Proprietary Page 13 Package Configuration ...

Page 14: ...cable Connect the DC power supply to the repeater Check the repeater LED indicator is in green Install the donor antenna SRF_HP1_ANT_B20B3B1 Choose the suitable location for the antenna and make holes to secure the bracket on the wall Assemble the antenna to the bracket on the wall Refer to the graphic below There are two ways to install the repeater The bracket supports both mounting on the wall ...

Page 15: ...roduct Manual V1 7 DEC 2021 2021 SOLiD Inc All Rights Reserved Confidential Proprietary Page 15 B Install the repeater Table standing type Find suitable location to place the bracket that is enclosed with the repeater in the package ...

Page 16: ...tWAVE SRF L 8A1821 Product Manual V1 7 DEC 2021 2021 SOLiD Inc All Rights Reserved Confidential Proprietary Page 16 C Clearance When placing the repeater it requires the minimum space to keep distance from another ...

Page 17: ...ll Rights Reserved Confidential Proprietary Page 17 Remove the cover to the USIM slot on the left side by loosening the screw on the lower left corner of the repeater Insert a USIM card into the slot as described as below pictures To remove the USIM card push the inserted card ...

Page 18: ...d follow the instruction to finish the installation 2 Click DT_GUI icon on the desktop B Run LMT DT_GUI 1 When DT _GUI runs it asks to login Enter admin for initial password and click Login button 2 When the login is successful a repeater model selection popup appears When the popup appears check Auto Select If you want to select repeater model manually uncheck Auto Select and then select SRF L 8A...

Page 19: ...SOLiD RocketWAVE SRF L 8A1821 Product Manual V1 7 DEC 2021 2021 SOLiD Inc All Rights Reserved Confidential Proprietary Page 19 No Description Repeater model name ...

Page 20: ...user controllable panel for the reporting function of the repeater status Available to setup re porting period and time and reference time Also provides reporting on and off button Displays the information of the repeater s Plug and Play function When the repeater is connected to the upper layer NMS the IP addresses APN and certificate information appears Provides user controllable panel for the r...

Page 21: ...ovides the AMP s OFF reason and AGC controllable panel When the AMP is off by the user it shows User Control for its reason For the AGC function AGC mode changing button its level control ler and function on and off are available To turn on the AGC click Then the button changes to Provides the Isolation controllable panel Click to perform Isolation Recheck When the re peater measures the isolation...

Page 22: ...t Interface Antenna Port 1 port for donor antenna SMA female type USB port 1 port for debugging behind blend Operating Temperature 5 to 50 Storage Temperature 5 to 50 Operating Humidity 5 to 90 IP Rate IP30 Stand and Wall Bracket Size Dimension W x H x D 92 6 x 169 x 10 mm Weight 45 g Mounting Type Wall mounting and Standing Colour RAL 9010 Material Poly Carbonate PC RF Specification Supported Ban...

Page 23: ...Total UL 18 dBm Total 18 dBm Total 18 dBm Total Service Antenna Gain DL 1 dBi 2 dBi 3 dBi Gain w o Antenna Gain DL max 64 dB max 64 dB max 64 dB UL Noise Figure UL max 8 dB max 8 dB max 8 dB Flatness Passband ripple 4dB p p 4dB p p 4dB p p EVM max 3 5 256QAM max 8 64QAM max 3 5 256QAM max 8 64QAM max 3 5 256QAM max 8 64QAM VSWR max 2 0 1 max 2 0 1 max 2 0 1 Delay max 3us max 3us max 3us AGC Respon...

Page 24: ...mit Solid orange This alarm is raised when output power is being lower than lower limit for 5mins Access to the LMT and check input power level Check cable connection status between a Donor An tennas Check the device output lower limit level is set cor rectly If the input power is normal but the output power reaches up to lower limit check the antenna isolation is sufficient If the isolation is no...

Page 25: ... the isolation is not sufficient between antennas Change the location of the repeater or change the loca tion of the antenna Recommended isolation value should be higher than below PLL Unlock Solid red This alarm is raised when the local fre quency is not generated due to PLL abnor mal operation Turn the device power off and on and check the re peater operates correctly If not replace the repeater...