background image

GENESIS

TM

 DAS Operation Manual - Version 0.0 – Jan. 2019 

©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.   

Page 20 

4.1.3  LRN Front and Rear Panel 

4.1.3.1 

Front Panel 

 

Figure 4.3 LRN Front Panel View 

 

 

4.1.3.2 

Rear Panel 

 

Figure 4.4 LRN Rear Panel View 

 

 

 

 

No 

Item 

Description 

  ANT 

External antenna interface port 

No 

Item 

Description 

  HOU(SFP+) 

Port to transmit / receive data connected to Cascade LRN 

 

LED 

Red

 

LRN is abnormal 

Blue 

LRN is normal 

Off 

Power is not activated 

 

HOU(SFP+) 

Port connected to the HOU to transmit / receive data 

④ 

DC IN 

Port receiving DC 57V from HOU or EPSU 

Summary of Contents for GENESIS DAS

Page 1: ... 2019 SOLiD Inc All Rights Reserved Confidential Proprietary Page 1 GENESISTM DAS Installation and Maintenance Version 0 0 Feb 2019 ...

Page 2: ...ncluding graphics and screenshots are current as of the date of publication SOLiD reserves the right to change the contents without prior notice In no event shall SOLiD be liable for any damages resulting from loss of data loss of use or loss of profits SOLiD further disclaims any and all liability for indirect incidental special consequential or other similar damages This disclaimer of liability ...

Page 3: ...GENESISTM DAS Operation Manual Version 0 0 Jan 2019 2019 SOLiD Inc All Rights Reserved Confidential Proprietary Page 3 Revision History Revision Issue Date Section Changes ...

Page 4: ...pacities 12 System Specifications 13 3 1 General Specifications 13 3 2 Ports and Environment Specifications 13 3 3 Downlink Specifications 14 3 4 Uplink Specifications 15 System Configuration and Functions 16 4 1 Low power Radio Node LRN 16 4 1 1 LRN Specifications 16 4 1 2 LRN Functions and Description 17 4 1 3 LRN Front and Rear Panel 20 4 1 3 1 Front Panel 20 4 1 3 2 Rear Panel 20 4 1 4 LRN Ins...

Page 5: ... Page 5 List of Illustrations Figure 2 1 GENESISTM Network Topology 11 Figure 4 1 LRN Front Side and Rear Views 16 Figure 4 2 LRN Appearance 17 Figure 4 3 LRN Front Panel View 20 Figure 4 4 LRN Rear Panel View 20 Figure 4 5 LRN Installation Clearance 21 Figure 4 6 LRN Power Cabling 24 Figure 4 7 LRN SFP Ports 25 ...

Page 6: ...cription UPOI Universal Point of Interface UPIU UPOI Point of Interface Unit DAU Distribution Aggregation Unit DRFU DAU RF Unit DDTU DAU Digital Transceiver Unit DPSU DAU Power Supply Unit DFAN DAU FAN DCU DeCode Unit HOU Hub Optic Unit HODTU HOU Digital Transceiver Unit HOPSU HOU Power Supply Unit HOFAN HOU FAN EPSU Expansion Power Supply Unit LRN Low power Radio Node RBU RN Base Unit LPMU LRN Po...

Page 7: ... carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer This could cause fires electric shock or other injuries Any repeater including this repeater will generate radio signals and thereby give rise to electromagnetic fields that may be hazardous to the health of any person who is extensively exposed to the signals at the immediate proximity of the...

Page 8: ...2019 SOLiD Inc All Rights Reserved Confidential Proprietary Page 8 Rotating fan Blade Can cause serious injury or pain Keep hands clear Turn off and lock out unit before servicing CAUTION Do Not Open Except at Approved Field Force Protective Work Station ...

Page 9: ...iding communication services at every corner of buildings the system enables users to make a call at any site The GENESISTM system supports communication standards and public interface protocols in worldwide use Frequencies 700MHz 800MHz 1900MHz 2100MHz 2300MHz 2500MHz etc Technologies GSM EDGE CDMA2000 1XEVDO WCDMA LTE APCO 25 etc GENESISTM is in modular structure per frequency band To provide de...

Page 10: ...llent Architecture Performance Advanced platform of mix and match topology any RN connection Near far mitigation functions digital filtering and fast ALC function Low power consumption high linearization technology Flexible Scalable Deployment Support any band combination simply plug in as your network grows Modular plug in and play structure easy management and expandable High Capacity Evolution ...

Page 11: ...distributes digital signals to HOU via optical fiber Decode Unit DCU Interface with DAU via UTP cable CAT5 Decode signals input to DAU and Decode information is used for system Auto Setup Hub Optic Unit HOU Interface with LRN via optical cable Support the daisy chain of HOU to reduce the number of optical fiber cables Expansion Power Supply Unit EPSU Interface with HOU via D SUB cable Supply DC 57...

Page 12: ...slot supports three 3 input ports DAU can have up to six 6 RF interface module slots and each slot supports four 4 input ports DAU can support up to two 2 Expansion DAUs Adding two 2 Expansion DAUs to the main DAU a system can support up to seventy two 72 cell interfaces Main DAU can drive up to sixteen 16 HOUs HOU can drive up to eight 8 LRNs via optical cables LRN can support up to six 6 RF band...

Page 13: ...m Power Cable AWG 14 to 24 VSWR 1 5 1 DAU 1 8 1 LRN Uplink Frequency Error 0 01ppm System Delay 8usec 1 0usec raise whenever node is added in daisy chain Item UPOI DAU DCU HOU EPSU LRN Input Connector 4 3 10_F 24 QMA_F 24 DL UL QMA_F 24 UL MCX_F 24 _Mon QMA 24 DAU Optic 1 DAU Optic 1 HOU Output Connector QMA_F 24 Optic 2 E DAU Optic 8 HOU RJ45 1 DAU Optic 1 HOU Optic 8 LRN NEX 10 1 External ANT In...

Page 14: ... kg 31 17 5 4 36 4 15 10 1 7 5 Item Specification Remark Ripple 4dB Peak to peak Input level UPOI 47 30dBm Max 50dBm No destructive DAU 30 0dBm Max 33dBm No destructive Output power LRN 20dBm 1GHz 15dBm 1GHz 17dBm 2300W Band Per band System Gain LRN 10 20dB 1GHz 15 15dB 1GHz 13 17dB 2300W Band Gain Control 0 50dB DAU Output Control 0 25dB RN Out of Band Gain 3GPP TS 25 106 Section 8 and 3GPP TS 36...

Page 15: ...tem Specification Remark Ripple 4dB Peak to peak Input Level Nominal 40dBm Max 38dBm No destructive by ALC function RN per band Output Power Duplexed port 15dBm total DAU Simplex port 35dBm total System Gain Duplexed port 30dB RN to DAU Simplex port 10dB Gain Control 0 50dB DAU EVM LTE 8 64QAM UMTS 12 5 Noise Figure 14dB ...

Page 16: ...SOLiD certified facilities by SOLiD certified personnel The mix of service bands can be achieved for example six 6 different bands are available The composite RF power per band is 15dBm below 1GHz 20dBm upper 1GHz and 17dBm 2300W Band Figure 4 1 LRN Front Side and Rear Views 4 1 1 LRN Specifications Item Specification Remark Size mm 390 x 300 x 74 Weight kg 7 5 Full Load Power Consumption W 75 Ope...

Page 17: ...nations of service bands and sectors Typical configurations of LRNs are six 6 band SISO MAIN KEY FEATURES Supports 6 bands 15dBm below 1GHz 17dBm 2300W Band 20dBm upper 1GHz output power per band 10Gbps over an optical cable External antenna ports available IP20 rated and optional IP66 supported Wall or ceiling mounting options 256 QAM supported COMPONENT DESCRIPTION Figure 4 2 LRN Appearance ...

Page 18: ...tions and quantities Part Unit Description Qty RBU Support 1 SFP port for interfacing with HOU via optical cable Support 6 bands Convert digital signal into downlink RF signal Convert uplink RF signal into digital with digital filtering technology Control and monitoring system status 1ea LPMU Amplify downlink RF signal and then filter the signal Filter and amplify uplink RF signal Support external...

Page 19: ... shows the LPMU specification LRFU Types Uplink Downlink Range BW Range BW LPMU_700_8085_1900_2100_2300_2500 699 716 17 729 768 39 776 798 21 817 849 32 862 894 32 1850 1915 65 1930 1995 65 1710 1780 70 2110 2180 70 2305 2315 10 2350 2360 10 2497 4 2687 4 190 2497 4 2687 4 190 Item Specification Remark DL Output Power 20dBm composite power per band UL Input Power Max 40dBm w o ALC function Max 38d...

Page 20: ...LRN Front Panel View 4 1 3 2 Rear Panel Figure 4 4 LRN Rear Panel View No Item Description ANT External antenna interface port No Item Description HOU SFP Port to transmit receive data connected to Cascade LRN LED Red LRN is abnormal Blue LRN is normal Off Power is not activated HOU SFP Port connected to the HOU to transmit receive data DC IN Port receiving DC 57V from HOU or EPSU ...

Page 21: ... the ceiling or wall for heat dissipation and cable access as shown below The clearance might be increased depending on the flexibility of cable Figure 4 5 LRN Installation Clearance There are two LRN installation mount brackets as shown below Installation Items Required Accessories Qty Included Tool Remark LRN Enclosure M6 Anchor Set 4 X 2 screw driver Ext Antenna Connection RF cables SMA type 4 ...

Page 22: ... wall bracket 2 Drill 4 four holes at the marked position 3 Secure the wall bracket to the wall or ceiling using the 4 four M6 anchor sets 4 Slide the LRN into the wall bracket and lift it up to be caught on the bracket 5 Screw the captive screw on the wall bracket using T20 Torx screwdriver to secure the LRN tightly The mounting bracket set has the special structure to prevent the LRN from fallin...

Page 23: ...etary Page 23 B CEILING MOUNTING BRACKET 1 Combine LRN and ceiling mount with 4 four M4 screws 2 Position the LRN in the direction shown below 3 Adjust the ceiling mount to the ceiling frame interval you want to install 4 Tighten the ceiling frame with M4 and M6 screws in the screw hole of the ceiling mount ...

Page 24: ...OWER CABLING The LRN can use DC power supply from HOU Power cables DC are not provided because different length of cables depends on field situation and different types of jack in each country Figure 4 6 LRN Power Cabling The recommended power cables AWG 14 to 24 is dependent on each country User can seek easily in the market ...

Page 25: ...ollowing table shows SFP type each SFP ports on the LRN based on mode LRN or Daisy chain LRN Complete the following tasks before inserting the SFP module Inspect and clean the fiber tips coupler and connectors Prepare and clean an external attenuator if needed When handling fiber cables take the following precautions to prevent damage to the cable No Mode Port Name 400m 1 LRN HOU LRN SFP 10G SR Bl...

Page 26: ...o remove an SFP Module Disconnect the optical cable from the SFP module Unlatch the SFP module Pull the SFP module out of the port on the LRN WARNING Optical SFPs contain Class 1 lasers Invisible laser radiation can occur when laser connections are unplugged Do not stare into the beam This device is compliant with FCC 21 CFR 1040 10 and EN60825 1 2007 Use of unauthorized antennas cables and or cou...

Page 27: ...Version 0 0 Jan 2019 2019 SOLiD Inc All Rights Reserved Confidential Proprietary Page 27 The following shows optical fiber based on SFP type No SFP Types Optical fiber Connector Ferrule type Remark 1 SFP 10G SR 2 optical fiber LC UPC ...

Page 28: ...S LRN Digital board receives optical data from HOU over optical cable And then convert into RF signal System information shows a lot of CPU firmware version temperature serial number and so on Actual delay value between HOU and LRN Delay value to be compensated as target delay Target delay LPMU is installed at the LRN Its LPMU can be hot pluggable Whenever LPMU installed LRN system detect that LPM...

Page 29: ...GENESISTM DAS Operation Manual Version 0 0 Jan 2019 2019 SOLiD Inc All Rights Reserved Confidential Proprietary Page 29 Band information DL Output power DL UL Amp on off UL Input power ...

Page 30: ...perate this equipment RF EXPOSURE STATEMENT The product complies with the FCC Fixed RF exposure limit set forth for an uncontrolled environment and is safe for intended operation as described in this manual RSS GEN SEC 7 1 2 TRANSMITTERS Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by In...

Page 31: ... et l impédance requise pour chaque type d antenne Les types d antenne non inclus dans cette liste ou dont le gain est supérieur au gain maximal indiqué sont strictement interdits pour l exploitation de l émetteur RF RADIATION EXPOSURE This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum d...

Page 32: ...FCC Licensee to operate this device You MUST register Part 90 Class B signal boosters as defined in 47 CFR 90 219 online at www fcc gov signal boosters registration Unauthorized use may result in significant forfeiture penalties including penalties in excess of 100 000 for each continuing violation IC Booster warning WARNING This is NOT a CONSUMER device It is designed for installation by an insta...