Confidential & Proprietary 22/35
4.1.2
How to expand ADD ON ROU at the Remote Unit
Remote Unit can expand ARU up to 1. The three item is needed for connection between Remote Unit
and ADD ON ROU. ADD ON ROU’s components additively have 3 item except for enclosure like below
Accessories
Description
Qty
Specification
Remark
1
TX RF Cable
1
N(M) ST to SMA(M)
ST_1.5M
2
RX RF Cable
1
N(M) ST to SMA(M)
ST_1.5M
3
I/O Cable
1
IEC 61076-‐2-‐
101(8pin_F)
ST_1.5m
4
Power Cable
(AC type only)
1
MIL-‐5015(16-‐10_F)
ST to Circular(eco
mate 3+PE_M)
ST_1.5m