AWS 900 Calibration Tutorial
2
AWS 900 Tutorials
Figure 2 – Room Set up
Adjusting each loudspeaker with the AWS 900
Turn on the console oscillator OSC ON and select the pink noise PINK ON; the default for the console's pink
noise output is +4dBu RMS. Adjust using the Pink trim pot in the oscillator section if necessary (see Figure 3).
To view the level of the pink noise, firstly cut the main monitor level and press the REC or MIX bus switches
near the Oscillator controls, and the level will be shown on the VU meters on the console. The corresponding
level for +4dBu RMS is 1.23V.
Figure 3 - Pink Noise
Set the monitor level control to the position you wish to correspond to the calibrated level. A value of 8.5 will
provide 10dB of additional gain in hand.
Figure 4– Monitor Level