Solid State Logic 82S6XR0A0B User Manual Download Page 7

Page A-5

X-Rack Mic Amp Module

A.4 Calibration Information

The X-Rack Mic Amp module is factory calibrated and should only need calibration if a potentiometer or
other component has been replaced or if it is suspected that there is a problem with calibration.

In each of the following instructions it is assumed that the lid of the X-Rack has been removed and that
power has been applied. It is also assumed that unless otherwise specified, all switches are released and
all front panel potentiometers are at unity or minimum position as appropriate. The required accuracy for
each adjustment will be specified along with the target value. All level and distortion measurements
should be made with audio-band 20Hz to 20kHz filters unless otherwise specified.

All presets are accessible from the top of the unit.

A.4.1 Microphone Input

Equipment Required:

Calibrated audio oscillator and audio level meter

Test Signal:

50Hz sinewave @ –12dBu, common mode

Input and Output:

Oscillator to Mic Input and Output to the audio level meter

Unit Setup:

Set the Mic Gain to ‘36dB’ (mid-position)

CMRR Trim

Adjustment:

Adjust VR7 (CMRR) for minimum level (normally < –40dBu)

A.4.2 Line Input

Equipment Required:

Calibrated audio oscillator and audio level meter

Test Signal:

1kHz sinewave @ 0dBu

Input and Output:

Oscillator to Line Input and Output to the audio level meter

Unit Setup:

Set the Line Gain to indent (0dB) and select ‘LINE’

Level Trim

Adjustment:

1. Adjust VR6 (0dB) for 0dBu ±0.05dB.

A.4.3 Output Balance

Equipment Required:

Calibrated audio oscillator, audio level meter and a ‘balance’ adaptor (see
below)

Test Signal:

1kHz sine wave at +24dBu

Input and Output:

Oscillator to Line Input and Output to the audio level meter via the
‘balance’ adaptor

Unit Setup:

Set the Line Gain to indent (0dB) and select ‘LINE’

Adjustment:

Adjust VR8 (BAL) for minimum level (< 55dBr)

A.4.4 ‘Balance’ Adaptor

For the output balance adjustment, a ‘balance’
adaptor such as that illustrated here will be
required. This adaptor consists of a pair of close
tolerance resistors in an in-line cable and is
used to sum together a balanced output in
order to correctly adjust the level balance of the
measured output; perfect balance should result
in complete signal cancellation.

5K01**

5K01**

2

3

1

2

3

1

0V

+

0V

+

 To measuring 
 equipment  

 From unit 

 under test 

  1  

  2  

  1  

Resistor tolerance should ideally be 0.01%
Absolute level measured will depend upon the input
impedence of the measuring equipment.

1.
2.

 Note

Summary of Contents for 82S6XR0A0B

Page 1: ... available free of charge from your local distributor if the X Rack unit concerned is in warranty For units that are out of warranty a small charge will be made The absence of this kit is indicated by the buscard in the X Rack being a 629620X1 RE 1 rev 1 with a number of components ie IC2 C4 L4 missing For correct operation of Total Recall your X Rack unit must be running V1 1 0 or later software ...

Page 2: ......

Page 3: ...MP IN switch and adjusting the Z control This allows the connection of line level signals to the Microphone input if required and provides an alternative input impedance for some dynamic microphones The PAD switch reduces the signal level of both the Microphone or Instrument inputs by 20dB Phantom power for microphones requiring this can be switched on using the 48V switch Please note that X Rack ...

Page 4: ...C L and REC R which route the module signal onto a common internal record bus The signal present indicator measures signals immediately prior to the output amplifier It will light GREEN for output signals above the lower threshold of 60dBu AMBER for signals between 4dBu and 24dBu and lights RED for signals above 24dBu The record bus is not currently used but may be used by forthcoming X Rack modul...

Page 5: ...hted measurements are specified as 22Hz to 22kHz band limited RMS and are expressed in units of dBu All distortion measurements are specified with a 36dB Octave low pass filter at 80kHz and are expressed as a percentage The onset of clipping for headroom measurements should be taken as 1 THD Unless otherwise quoted all figures have a tolerance of 0 5dB or 5 All measurements are made with the opera...

Page 6: ...kHz 18dBu applied 28dB gain 0 05 at 10kHz Frequency Response 0 05dB 0 1dB from 20Hz to 20kHz 3dB at 150kHz Equivalent Input Noise 82dB at 12dB minimum gain Input terminated with 150Ω 88dB at 28dB gain mid position A 2 5 Line Input Performance Signal applied to Line Input and measured at Output Input Gain control set to 0dB indent Gain Continuously variable from 20dB to 20dB Input Impedance 10kΩ TH...

Page 7: ... for minimum level normally 40dBu A 4 2 Line Input Equipment Required Calibrated audio oscillator and audio level meter Test Signal 1kHz sinewave 0dBu Input and Output Oscillator to Line Input and Output to the audio level meter Unit Setup Set the Line Gain to indent 0dB and select LINE Level Trim Adjustment 1 Adjust VR6 0dB for 0dBu 0 05dB A 4 3 Output Balance Equipment Required Calibrated audio ...

Page 8: ... panels are offset Weight 260g 9 5 ounces Boxed size 190mm x 290mm x 70mm 7 5 x 11 5 x 2 5 Boxed weight 460g 16 5 ounces All values are approximate A 7 Environmental Specification As per X Rack see page 17 Instrument Input Location Front Panel Conn Type Mono 1 4 Jack Socket Pin Description Tip Guitar Input Sleeve Chassis Audio Output Location Rear Panel Conn Type XLR Male Pin Description 1 Chassis...

Reviews: