Solex Roofing Installation Manual 41
Solex Energy Ltd +44(0)1305 837223 www.solexenergy.co.uk
Controller display
First parameters:
To move beyond these keep
RIGHT pressed for 2 seconds. Factory default settings should be
used, except for the following:
Parameter
Meaning
Set to
Arr
Program for different system layouts
As required
DT O
Switch on temperature difference
4.5
o
C
DT F
Switch off temperature difference
2.5
o
C
S MX
Maximum store temperature (Hot water should be 55-65
o
C) As
required
PRIO
Store priority. Set to hot water store on 2 store systems
1,2 etc
nMN
Minimum pump speed. Default setting 30%
As required
HND1, HND2
Manual mode R1,R2. Use to test system, then set to auto
Auto
For other parameters refer to the instruction book supplied or at
www.solexenergy.co.uk
,
or
www.resol.de
.
Maintenance
Generally, very little maintenance is required.
Roof maintenance
•
Cleaning
– these roofs do not need routine cleaning. There has been no history of
moss or lichen build up on these roofs, due to the natural weathering, and the
temperatures the glazing reaches in the sun.
•
Breakages
– glass roof slates are very robust, being stronger than natural slates.
They are edge sensitive however, and a lucky strike by a large stone or similar hard
object could break one. When broken they disintegrate into small fragments like
automobile glass
•
Removal & replacement, Solar Slates
– if broken, clean out the remaining fragments,
and bend the slate clip down. If intact, bend the clip down and ease the slate out
downwards. Push in a new slate, watching that it does not catch on the adjacent
screws. Silicone oil lubricant may be used to ease installation. Bend the clip back with
care to hold it in place.
•
Removal & replacement, Nu-lok Slates
– if broken, clean out the remaining
fragments. If intact, push the slate up by about 5mm, push the wire clips to the sides
and drop the slate out. To replace, move the stainless wire clips to the sides and push
up a new slate. Silicone oil lubricant may be used to ease installation.
Faults
Indicated by flashing symbols on the display
Readings
888.8 = sensor line break -88.8 = sensor line short
Controller LED
Red=standby
/
Green=pump operating
/
Flas
hing
=malfunction
COL, COL1, COL2
Collector temperature(s)
TST, TST1, TST2
Store temperature(s)
n%, n1%, n2%
Pump speed
h P
System operating hours
Faults
Indicated by flashing symbols on the display