background image

 

 10 

 

USING YOUR AIR CONDITIONER 

Electronic Control Panel & Remote Control 
 
 
 

 

1. 

Power Button: 

Turns the air conditioner on and 

off 

2. 

Digital Display: 

Displays the current room tem-

perature or the amount of time left on the timer. 
Shows the Set Temp when setting the tempera-
ture. Shows the Timer Set when setting the timer. 
The once the timer and/or temperature are set, 
the display will change to show the current room 
temperature. To see the set temperature again, 
simply press either of the Temp/Delay 

/

 

buttons. 

 

 

3. 

Temperature Set: 

Use these buttons on the con-

trol panel and remote to increase or decrease the 
Set Temperature (the desired room temperature) 
in cooling or energy saver mode. The 

SET 

light 

will light up when setting the temperature 

4. 

Timer Set: 

Use these buttons on the control 

panel and remote to set the Timer. Each press of 
the Timer (

DELAY

) buttons will increase or de-

crease the timer. For timer instructions see #7. 

5. 

Fan Speed & Auto Fan

: Use the fan speed but-

tons to change the fan speed. Choose between 
low, medium, high, and Auto. When using the re-
mote control, press the 

AUTO 

button to turn auto 

mode on and off and the 

FAN+ 

and 

FAN– 

buttons 

to select low, medium, or high fan speed. 

6. 

Mode Button: 

Press the mode button to cycle 

through the various modes: Cooling, Energy 
Saver, Fan only, and Dry (Dehumidifier). 

7. Auto-on 

Timer: 

When the air conditioner is off, it 

can be set to automatically turn on in 1-24 hours 
at the previous set mode and fan setting. To set 
the Auto-on Timer, press the 

TIMER 

button on the 

unit or remote control. Each touch of the 

/

 on 

the unit or the +/- buttons on the remote will 
change the timer setting in 1 hour intervals. The 

SET 

light will turn on while setting.

 

Auto-off Timer: 

When the air conditioner is on, it 

can be set to automatically turn off in 1-24 hours. 
To se the Auto-off Timer, press the 

TIMER 

button 

on the unit or remote control. Each ouch of the 

/

 on the unit or the +/- buttons on the remote will 

change the timer setting in 1 hour intervals. The 

SET 

light will turn on while setting. 

• 

To see the remaining time, press the 

TIMER 

Button. To change the timer setting use the 

/

 on the unit or the +/- buttons on the 

remote. 

• 

To cancel the timer, press the 

TIMER 

button 

until the 

SET 

light turns off.

 

8. 

Filter Check: 

After the fan rotates for 250 total 

hours, the filter check light will turn on to remind 
the user to clean the filter. Press the Filter check 
button once the filter is cleaned to reset the re-
minder.

 

Air Conditioner Controls 

NOTE: This display always shows the room temperature 

except when setting the Set temperature or the Timer. 

When the light is on the unit is in 

temperature or timer set mode. 

Normal Operating Sounds 

• 

You may hear a pinging noise caused by water 
hitting the condenser, on rainy days, or when the 
humidity is high. This design feature helps re-
move moisture and improve efficiency.  

• 

You may hear the thermostat click when the com-
pressor cycles on and off. 

• 

Water will collect in the base pan during rain or 
days of high humidity. The water may overflow 
and drip from the outside part of the unit. 

• 

The fan may run even when the compressor is 
not on. 

Summary of Contents for SG-TTW-12ESEZ-26

Page 1: ...Models SG WAC 10ESE C SG WAC 12ESE C Electronic Window Air Conditioner Operating Instructions ...

Page 2: ...ead this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the following basic precautions 2 This is a safety alert symbol This symb...

Page 3: ...when the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch The power supply cord is designed as a protection device A damaged power supply cord must be replaced with a new power supply cord from Soleus Air Powered by Gree The power supply cord contains new user serviceable parts Opening the tamper resistant case voids all warranty and per forma...

Page 4: ...ote Control AAA Batteries 2 Top Mounting Rail Top Mounting Rail Seal Strip Lock Frame 2 Accordion Panels Left Right Sash Lock 1 Window Sash Seal 3 4 Screw for Window Locking Bracket Accordion Panels and sash lock 6 Foam Top Window Gasket Owner s Manual 4 ...

Page 5: ...RNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN 5 Model SG WAC 10ESE C Power Supply Ph V Hz 1 115 60 Rated Cooling Capacity BTU h 10 000 Cooling Power Input Watts 930 Rated Current Cooling Amperage 8 6 EER C O P 10 8 Noise Level dB A H M L 54 52 50 CFM H M L 260 240 220 Dehumidifying Capacity 60 Pints per day Product Dimensions W x H x D ...

Page 6: ...mensions 3 The Lower Sash the lower part of the window that moves up and down must allow for 14 5 of vertical clearance when open See FIG 1 4 All supporting parts must be secured to firm wood masonry or metal 5 The electrical outlet must be within reach of the power cord TOP RAIL INSTALLATION 6 NOTE Save the product packaging and installation instruc tions for future reference Store the air condit...

Page 7: ...proper condensation utilization and drainage If you are not using the side panels the rear pitch must still be main tained 1 Remove the backing from the top mounting rail seal strip and attach the seal strip to the bottom of the top rail Align along the front edge 2 Attach the top rail onto the top of the outer case using the four 2 5 screws 7 ...

Page 8: ... and into the sill FIG 9 NOTE To prevent window sill from splitting drill 1 8 3mm pilot holes before driving screws Accordion Panel Installation Now that you have installed the top rail you can now install the accordion panels on each side 1 Place the air conditioner on a hard flat surface 2 Locate the accordion panels in the box 3 Gently pull the free end of the accordion panel See FIG 2 Do this ...

Page 9: ... a depth of at least 1 1 2 Make sure the board or piece of wood is ap proximately 1 2 higher than the storm window frame This will allow the air conditioner to tilt enough for proper drain age See FIG 12 Removing the Air Conditioner from the Window 1 Turn the air conditioner off and disconnect the power cord 2 Remove the sash seal from between windows and unscrew sash lock 3 Remove the screws inst...

Page 10: ...etting To set the Auto on Timer press the TIMER button on the unit or remote control Each touch of the on the unit or the buttons on the remote will change the timer setting in 1 hour intervals The SET light will turn on while setting Auto off Timer When the air conditioner is on it can be set to automatically turn off in 1 24 hours To se the Auto off Timer press the TIMER button on the unit or re...

Page 11: ...tioner will cool the area depending on the location and set temperature of the remote control Take the remote control with you so the air conditioner cools the room to your loca tion The Remote must be in line of site of the A C for iFeel to operate correctly 7 SLEEP MODE Press the SLEEP button to turn SLEEP mode on or off SLEEP mode is set to off automatically When SLEEP mode is selected the time...

Page 12: ...and buttons a the same time 11 DISPLAY LIGHTS Hold the and FAN buttons to turn the light s on the display ON or OFF This can be done when the unit is on or off 12 ENERGY SAVER MODE When the unit is in energy saver mode the Energy Saver light will turn on In Energy Saver mode the unit will turn off once the room is cooled to the user set temperature The fan will also be off at this point The unit w...

Page 13: ...the Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take approximately 3 minutes for the compressor to start and cooling to begin Energy Saver Mode Controls the Fan On The fan will cycle on and off with the compressor This results in winder variations of r...

Page 14: ...d Tear To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping Cabinet Cleaning To clean the air conditioner cabinet Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free ...

Page 15: ...ce technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is escaping The Cooling Coils are frozen Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Lower the set thermostat tempera ture Clean the filter See ...

Page 16: ...r is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short period in areas with low humidity and nor mal for a longer period in areas with high humidity 16 ...

Page 17: ...by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL...