background image

  

When the temperature or humidity is too high, the air conditioner may not be able to evaporate all of the water 

as quickly as needed. All moisture that is unable to be evaporated is placed in a small bank up water tank in-

side the unit. When this tank is completely full, an alarm will sound, the compressor will shut off, and the 

bucket full icon will light up on the control panel. To manually empty the tank, please follow the instructions 

below. 

1)  Remove the pre-installed Drain Cap from the unit (See Below).  

2)  Attach the Clamp with the provided Screw (See Below). 

3)  Attach the Drain Hose to the Drain Port using the Drain Hose Clip. Insert the Drain Plug into the free end 

of the Drain Hose and guide the Drain Hose through the Clamp. Once finished, the unit can be easily 

drained by removing the drain plug and guiding the drain hose into a small pan to drain the water. 

 

DRAINING COLLECTED WATER

 

Drain Hose 

Clamp 

Drain Hose Clip 

Drain Plug 

Screw 

A. Drain Port 

B. Clamp 

A. Drain Port 

B. Drain Cap 

A. Drain Plug 

B. Drain Port 

C. Drain Hose 

D. Drain Hose Clip 

E. Clamp 

 1

1

 

Summary of Contents for SG-PAC-08E4

Page 1: ...8 000 BTU Portable Air Conditioner Operating Instructions Model No SG PAC 08E4 Reference No KY 80E4 V 121016 ...

Page 2: ...anual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start o...

Page 3: ... hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button for use If a test is performed and the indicator light remains ON cur...

Page 4: ...PRODUCT DIAGRAM Control Panel Louvers Louver Guides Casters Power Cord Filters Upper Air Intake Lower Air Intake Remote Control Holder Air Exhaust Vent 4 ...

Page 5: ...ner Exhaust Hose 1 Exhaust Hose Adapter 1 Window Kit Adapter 1 Hose Adapter 1 Remote Control AAA Batteries 2 batteries Window Kit 3 Sliding Panels 1 single hose panel 2 extension panels Drain Hose Assembly drain pipe clamp hose clip rubber plug screw Owner s Manual Model Number SG PAC 08E4 Power Supply Ph V Hz 1 115 60Hz Dehumidifying Capacity Pints Day 38 Rated Cooling Capacity BTU h 8 000 Rated ...

Page 6: ...hoose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hose approximately 6 inches Screw the window kit adapter onto one end of the exhaust hose clockwise Screw the hose adapter onto the other end of the exhaust hose clockwise Mount the exhaust hose onto the back of the unit by locking the hose ...

Page 7: ...as flat as possible The less angles and bends in the hose the better the unit will perform If bending or an angle is necessary use single 90 angles like the pictures above Multiple bends will decrease performance and efficiency This installation is OK The is a poor installation 22 26 7 ...

Page 8: ...unit as a fan it is not necessary to keep the exhaust hose and window kit connected to the unit 3 Temperature Select the desired temperature by pressing either or key when using the unit in cooling mode The digital thermostat will display the set temperature 4 Louver Direction This unit has 4 Way directional louvers Use the louver guides to direct air where cooling or fanning is needed most 5 Buck...

Page 9: ...h fan speeds The small fan icons will light up depending on which speed is selected The more fan icons light up the higher the speed The fan icons are located on the LCD display next to the SPEED label 4 Temperature Setting When the unit is in Air Conditioner mode you can select your desired temperature Press the TEMP SELECT buttons or to select your desired temperature setting The temperature on ...

Page 10: ...F button to cancel the timer 6 Sleep Mode Press the SLEEP mode button to engage SLEEP mode Sleep mode automatically raises the set temperature by 2 F after one hour and 4 F after two hours This feature limits compressor usage and enhances energy savings while you are sleeping 7 Auto Mode When AUTO mode is selected the air conditioner will automatically choose the operating mode base on the current...

Page 11: ...nstructions below 1 Remove the pre installed Drain Cap from the unit See Below 2 Attach the Clamp with the provided Screw See Below 3 Attach the Drain Hose to the Drain Port using the Drain Hose Clip Insert the Drain Plug into the free end of the Drain Hose and guide the Drain Hose through the Clamp Once finished the unit can be easily drained by removing the drain plug and guiding the drain hose ...

Page 12: ...ried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess wate...

Page 13: ...ESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is escaping The Evaporator is frozen Make sure there are no curtains blinds or furniture blo...

Page 14: ...e LED Display is showing H8 The backup water tank is full Drain the water tank If the H8 is still displayed after the water tank has been emptied con tact customer service The LED Display is showing F1 The LED Display is showing F2 The room air temperature sensor malfunction The tube temperature sensor malfunction Please inform the maintenance man to maintain Please inform the maintenance man to m...

Page 15: ...r appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENT...

Page 16: ...66129906767 ...

Reviews: