1)

 

Power On and Off 

-

 When the unit is plugged in, press the 

POWER       

button to turn on the unit.  

Press the 

POWER 

button once more to turn the unit off. When in Air Conditioner mode, Auto mode, 

and Sleep mode, the selected temperature will appear on the remote control LCD display. When the 

unit is in Fan mode or Dehumidifier mode, room temperature will be displayed. Temperature selection 

is not available when the unit is in Fan mode and Dehumidifier mode. 

 

2)

 

Mode Selection 

-

 Press the 

MODE

 button repeatedly to cycle between the different modes: Auto, Air 

Conditioner, Dehumidifier, and Fan

-

Only mode. The mode icon on LCD display will light up showing 

which mode is selected. 

 

3)

 

Mirage Display

 

-

 Press the 

MIRAGE 

button to activate the Mirage Display on the front of the unit. The 

Mirage Display conveniently shows the ambient temperature from across the room or the temperature 

setting on the control panel.

 

4)

 

Fan Speed 

-

 Press the 

FAN SPEED 

button to choose desired fan speed. When the unit is in Dehu-

midifier mode, the fan speed cannot be changed. When Turbo Cool is activated, fan speed is automat-

ically set on high and is not adjustable in this mode.

 

5)

 

Temperature Setting 

-

 When the unit is in Air Conditioner mode, you can select your desired temper-

ature. Press the 

+

 or 

-

 to select your desired temperature setting. The temperature on the LCD display 

on the remote control will increase or decrease accordingly. Pressing the 

°C 

/

°F 

button will switch 

the temperature select between °C and °F. 

 

6)

 

SLEEP MODE  

-

 When in air conditioning mode, press the 

SLEEP 

button on the remote control, Sleep 

mode icon will show on the remote control LCD display. When in 

SLEEP 

mode, the fan will run on low 

to keep fan noise at a minimum. The temperature setting will gradually increase to 2°F above the origi-

nal set temperature each of first 2 hours. The unit will keep operating the same temperature until the 

sleep mode is turned off. 

 

7)

 

TIMER 

-

 

   

 

 

 

 

 

 

 

 

 

 

            

Auto

-

On: 

Press the 

TIMER 

button when the unit is off to set up the Auto

-

on timer. The hour indi-

cator on the LCD display will turn on. Press the 

+

 or 

-

 buttons to set timer within 1

-

24 hours.

   

Auto

-

Off: 

Press the 

TIMER 

button when the unit is On to set up the Auto

-

off timer. The hour indi-

cator on the LCD display will turn on, Press the 

+

 or 

-

 buttons to set timer within 1

-

24 hours. To cancel 

the timer, press 

TIMER 

button until the timer mode is turned off.

 

8)

 

TURBO COOL 

-

 Press the 

Turbo 

button

 

to activate Turbo Cool mode. The unit will cool at 61°F on fan 

high for 10 minutes and then return to the original settings. Fan speed is not adjustable in this mode.  

 

NOTE: 

If Fan mode activates less than 3 minutes and switches to Turbo Cool, it will be a compres-

sor protection shut down, compressor will turn on again until the 3 minutes is topped off. 

 

9)

 

MYTEMP MODE 

-

 Press the 

MYTEMP 

button to change the thermostat sensor from the air conditioner 

to the remote control location. The air conditioner will cool the area at the location and set temperature 

of the remote control. 

 

10)

 

CHILD LOCK

– Press this button to lock/unlock the remote control buttons.                     

 

 

 

 

REMOTE CONTROL 

 

Summary of Contents for PSH-08-01

Page 1: ...ted Cooling Capacity SACC Meets Department of Energy California Energy Standards OPERATING INSTRUCTIONS V210702 Air conditioner must be upright for 24 hours prior to operating This ensures that the co...

Page 2: ...rence 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm cl...

Page 3: ...temperature is higher than the max operating temperature or lower than the mini mum operating temperature the air conditioner may not work properly PACKAGE CONTENTS Model Number PSH 08 01 PSH 09 01 Co...

Page 4: ...xposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet the LED light will turn on 2 Press TEST Button...

Page 5: ...7 Air Discharge Opening 8 Air Intake Grilles 9 Condensation Drain Hole 10 Exhaust Hose 11 Exhaust Hose Connector 12 Window Kit Adapter 13 Window Kit Panels 14 Wing Nuts Screw 15 Optional Drain Tube 1...

Page 6: ...in air conditioning dehu midification When the unit is operating in Fan Mode no outdoor air exchange takes place The window kit and ex haust hose do not need to be installed when the unit is used as...

Page 7: ...ase into the small hole found on panel A 2 Screw the Wing Nut onto the Wing Nut Base until slightly loose Will tighten in an upcoming step 3 Slide panel B inside panel A and over the Wing Nut Base 5 T...

Page 8: ...door to adjust the length of the Window Kit Panels to fit the opening If necessary mark the kit and cut one end down to properly fit the opening 3 Twist the Exhaust Hose Connector over the discharge...

Page 9: ...mode The temperature indicator flashes to display the desired tem perature setting After the temperature is set the unit will display this temperature setting until it is changed by the user The tempe...

Page 10: ...LCD DISPLAY POWER BUTTON TIMER TEMP DECREASE CHILD LOCK BUTTON SLEEP BUTTON TIMER BUTTON TURBO COOL BUTTON C F SWITCH BUTTON FAN SPEED MY TEMP BUTTON REMOTE CONTROL MODE BUTTON MIRAGE DISPLAY BUTTON...

Page 11: ...witch the temperature select between C and F 6 SLEEP MODE When in air conditioning mode press the SLEEP button on the remote control Sleep mode icon will show on the remote control LCD display When in...

Page 12: ...ency NOTE When the unit is running on air conditioning mode the exhaust hose is required and must be vented outside using the supplied window kit Dehumidifier Mode 1 Install the exhaust hose and windo...

Page 13: ...rol panel display 4 Select the fan speed by pressing the FAN SPEED button 5 Temperature indicator displays room temperature NOTE It is not necessary for the exhaust hose and window kit to be installed...

Page 14: ...ter tank inside the unit The internal water tank holds approximately 1 5 liters of water When this tanks becomes full the unit will automatically shutdown and illuminate the Bucket Full indicator HOW...

Page 15: ...e water will drain out automati cally 4 When the drain pan is full install the drain plug back onto the condensation drain hole to stop the water flow 5 Empty the drain pan 6 Repeat steps 2 5 until al...

Page 16: ...nit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of...

Page 17: ...ing air discharge During operation there is an un pleasant smell in the room Air filter is dirty Remove air filters clean and re install Air conditioner does not operate after restarting the unit The...

Page 18: ...please call customer service at 833 669 9998 E2 Outdoor Exhaust Temperature Sensor Malfunction Turn the unit off Unplug the unit from the wall and plug it back in If this codes appears again please ca...

Page 19: ...of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by JHS INC Freight and Insurance cost for the warranty s...