IMPORTANT SAFEGUARDS 

 

Before installing and using your portable air conditioner and heater, it is important that you read this owner’s 
manual carefully. Store this manual in a safe place for future reference.   

 

This instruction manual is used for guidance and does not form part of a contract. It reserves the right to 
make technical changes without prior notice. 
 

1.

 

Always place the unit on a level surface. 

2.

 

The appliance shall be installed in accordance with national wiring regulation. 

3.

 

The unit must be connected to a correctly grounded power supply. For your safety, this unit is 
grounded through the power cord plug when connected to a grounded wall outlet. Do not use an 
adapter plug or extension cord. 

4.

 

Do not install the unit in an area where gas leakage may occur and/or in an explosive atmosphere.   

5.

 

Do not apply an insecticide or any type of flammable spray on the unit. 

6.

 

Confirm drainage piping is connected properly. 

7.

 

Do not start or stop the unit by inserting or pulling out the power plug. 

8.

 

Do not operate with wet hands. 

9.

 

Close supervision is necessary when the unit is used near children. The unit in not intended for use 
by children.   

10.

 

Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills.   

11.

 

Do not expose skin or eyes directly to cool air for a long period of time. 

12.

 

If an abnormal odor or smoke comes out of the unit, disconnect the unit immediately and contact a 
qualified service technician. (see page 13) 

13.

 

When opening the filter cover, do not touch the metal parts in the unit’s interior.   

14.

 

Do not immerse the unit in water or any type of liquid. Do not use the unit in the immediate 
surroundings of a bath, shower, or swimming pool, or in any other steamy, wet areas.   

15.

 

When cleaning the unit, always turn the unit off and unplug the power cord. 

16.

 

Always inspect the power cord for signs of damage before use. If the power cord is damaged, it must 
be replaced by the manufacturer or a qualified service technician. 

17.

 

Do not place a plant or allow a pet in the direct path of the airflow to avoid injury. 

18.

 

Do not put a stove, etc, where it would be exposed to the direct airflow. It may affect combustion. 

19.

 

Do not sit on the unit or place anything on it. 

20.

 

Before storing, the water must be drained from the unit and the filters cleaned.   

 

Summary of Contents for PH1-12R-03

Page 1: ...Conditioner Dehumidifier Heater and Fan utilizing Heat Pump Technology OWNER S MANUAL Model PH1 14R 03 Reference KY 36 PH1 12R 03 Reference KY 34 Please read owner s manual carefully before operating...

Page 2: ...7 CONTROL PANELAND MULTI COLOR DISPLAY 10 CONTROL PANEL FUNCTIONS 11 OPERATION USING THE CONTROL PANEL 12 COOLING 12 DEHUMIDIFYING 12 FANNING 12 HEATING 12 AUTO MODE 13 SLEEP MODE 13 REMOTE CONTROL O...

Page 3: ...m exhaust air When operating as an air conditioner this unit is designed for spot cooling or cooling a room no larger than 550 square feet with a standard eight foot ceiling height When using this app...

Page 4: ...upervision is necessary when the unit is used near children The unit in not intended for use by children 10 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills 11 Do...

Page 5: ...not grounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to chec...

Page 6: ...s E Casters F Cable power cord and plug BACK A Hot air outlet grill B Lower air inlet grill ACCESSORIES Flexible exhaust hose with 2 adapters 3 piece set stretches from 14 1 4 to 60 5 8 36cm to 150cm...

Page 7: ...AUST HOSE Slide the square end of the exhaust duct over the hot air outlet on the back of the unit The exhaust hose should be kept as short and straight as possible Prevent any sharp bends in the exha...

Page 8: ...e length of the window kit to fit the opening If the window kit is not long enough connect the extra window kit panel to fit the opening Mark and cut down a single panel of the window kit if necessary...

Page 9: ...9...

Page 10: ...creases the room temperature timer hours Button This button increases the room temperature timer hours Power Button Press this button to turn the unit on or off MODE Button Press this button to select...

Page 11: ...eously to change the display from Celsius to Fahrenheit or vice versa TIMER To set the auto start time press the Timer on button until the multi color display shows a flashing Press the and buttons to...

Page 12: ...t operates at low fan speed during dehumidifying The unit cools the room slightly during dehumidification Keep the windows and the doors closed to aid in the effectiveness of the unit in removing the...

Page 13: ...2 Press the Sleep button The icon appears on the multi color display 3 The fan motor runs at low speed 4 When in cooling mode the temperature will increase 1 F per hour during the first two hours Then...

Page 14: ...A batteries provided Install the batteries before using the remote control The remote control can be used to do all the operations that can be programmed from the control panel The LCD display on the...

Page 15: ...ater container is full 2 Place the drain pan accessory under the drainage port at the back of the unit 3 Remove the rubber plug from the drain hole The condensate water will drain out automatically Wh...

Page 16: ...Slide the filters out from the side of the unit Immerse the filter gently in warm water with a mild detergent Rinse thoroughly and dry before replacing An unclean air filter reduces air volume The fi...

Page 17: ...t Is the main power supply on Reestablish the main power supply Is the water container full indicator light on Empty the water container Unit does not operate or only runs in fan mode Is the timer set...

Page 18: ...FM 280CFM Power Source 115 V 60 HZ 115 V 60 HZ Cooling 12 A 11 7 A Rated Current Heating 9 8 A 9 5 A Sound Pressure Level 49 db A 49 db A Weight 80 lbs 80 lbs Dimensions 14 4 W x 22 4 D x 30 5 H inche...

Page 19: ...ts caused by wear 4 Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc 5 Freight and Insurance cost for the warranty service ALL WARR...

Reviews: