background image

 

13 

AUTO MODE 

1.

 

Properly install the exhaust hoses.   

2.

 

Plug the power cord into a grounded outlet. 

3.

 

Turn on the unit by pressing the On/Off button on the control panel. 

4.

 

Press the Mode button until the “

” icon appears on the multi-color display. 

5.

 

Press the Fan button to select the fan speed.   

During  the  Auto  mode, the  unit  operates  in  heating  mode  when  the  room  temperature  is  below  68

°

F.   

The  unit  operates  in  dehumidifying  mode  when  the  room  temperature  is  between  68

°

F  -  73

°

F.    The 

unit operates in cooling mode when the room temperature is above 73

°

F.    You may use the timer with 

the Auto mode. 

SLEEP MODE   

(This mode can only be programmed from the remote control.)   

1.

 

The air conditioner will need to be in operation. 

2.

 

Press the Sleep button. The “

” icon appears on the multi-color display.   

3.

 

The fan motor runs at low speed. 

4.

 

When in cooling mode, the temperature will increase 1

°

F per hour during the first two hours. Then 

the temperature will stay 2

°

F higher than the originally set temperature for 6 hours.    6 hours later, 

the unit will shut down. 

5.

 

When in heating mode, the temperature will decrease 1

°

F per hour during the first two hours. Then 

the temperature will stay 2

°

F lower than the originally set temperature for 6 hours. 6 hours later,

 

the 

unit will shut down. 

6.

 

When in dehumidify mode, the temperature will not change. 

 

NOTE:

 

If the unit is turned off during cooling, dehumidifying, or heating and then restarted, there will be a 3 

minute delay before the compressor will turn back on to prolong the life of the compressor. Once the power 
recovers and the compressor restarts, the unit will return to the original working mode.

 

Summary of Contents for PH1-12R-03

Page 1: ...Conditioner Dehumidifier Heater and Fan utilizing Heat Pump Technology OWNER S MANUAL Model PH1 14R 03 Reference KY 36 PH1 12R 03 Reference KY 34 Please read owner s manual carefully before operating...

Page 2: ...7 CONTROL PANELAND MULTI COLOR DISPLAY 10 CONTROL PANEL FUNCTIONS 11 OPERATION USING THE CONTROL PANEL 12 COOLING 12 DEHUMIDIFYING 12 FANNING 12 HEATING 12 AUTO MODE 13 SLEEP MODE 13 REMOTE CONTROL O...

Page 3: ...m exhaust air When operating as an air conditioner this unit is designed for spot cooling or cooling a room no larger than 550 square feet with a standard eight foot ceiling height When using this app...

Page 4: ...upervision is necessary when the unit is used near children The unit in not intended for use by children 10 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills 11 Do...

Page 5: ...not grounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to chec...

Page 6: ...s E Casters F Cable power cord and plug BACK A Hot air outlet grill B Lower air inlet grill ACCESSORIES Flexible exhaust hose with 2 adapters 3 piece set stretches from 14 1 4 to 60 5 8 36cm to 150cm...

Page 7: ...AUST HOSE Slide the square end of the exhaust duct over the hot air outlet on the back of the unit The exhaust hose should be kept as short and straight as possible Prevent any sharp bends in the exha...

Page 8: ...e length of the window kit to fit the opening If the window kit is not long enough connect the extra window kit panel to fit the opening Mark and cut down a single panel of the window kit if necessary...

Page 9: ...9...

Page 10: ...creases the room temperature timer hours Button This button increases the room temperature timer hours Power Button Press this button to turn the unit on or off MODE Button Press this button to select...

Page 11: ...eously to change the display from Celsius to Fahrenheit or vice versa TIMER To set the auto start time press the Timer on button until the multi color display shows a flashing Press the and buttons to...

Page 12: ...t operates at low fan speed during dehumidifying The unit cools the room slightly during dehumidification Keep the windows and the doors closed to aid in the effectiveness of the unit in removing the...

Page 13: ...2 Press the Sleep button The icon appears on the multi color display 3 The fan motor runs at low speed 4 When in cooling mode the temperature will increase 1 F per hour during the first two hours Then...

Page 14: ...A batteries provided Install the batteries before using the remote control The remote control can be used to do all the operations that can be programmed from the control panel The LCD display on the...

Page 15: ...ater container is full 2 Place the drain pan accessory under the drainage port at the back of the unit 3 Remove the rubber plug from the drain hole The condensate water will drain out automatically Wh...

Page 16: ...Slide the filters out from the side of the unit Immerse the filter gently in warm water with a mild detergent Rinse thoroughly and dry before replacing An unclean air filter reduces air volume The fi...

Page 17: ...t Is the main power supply on Reestablish the main power supply Is the water container full indicator light on Empty the water container Unit does not operate or only runs in fan mode Is the timer set...

Page 18: ...FM 280CFM Power Source 115 V 60 HZ 115 V 60 HZ Cooling 12 A 11 7 A Rated Current Heating 9 8 A 9 5 A Sound Pressure Level 49 db A 49 db A Weight 80 lbs 80 lbs Dimensions 14 4 W x 22 4 D x 30 5 H inche...

Page 19: ...ts caused by wear 4 Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc 5 Freight and Insurance cost for the warranty service ALL WARR...

Reviews: