background image

 

- 9 -

 
 

Installation 

 

 

               

Installation Location 

 

 

Indoor Unit 

 

1.

 

The inlet and outlet should not be covered so that the outflow air can reach all parts of the room. 

2.

 

Install in a location from which the condensation water can be drained out conveniently and that is 
permitting easy connection with the outdoor unit. 

3.

 

Avoid a location where there is heat source, steam or inflammable gas. 

4.

 

Install in a location where it can withstand the full weight and vibration of the unit. 

5.

 

Be sure to leave enough space to allow access for routine maintenance.  The height of the installation 
should be 7.55 feet or more away from the floor. 

6.

 

Install in a location where it is 3.28 feet or more away from other electric appliances such as television, 
audio devices, etc. 

7.

 

Select a location where it is easy to remove and clean the filter. 

8.

 

Be sure that the installation conforms to the installation dimension diagram. 

9.

 

The plug should be accessible after the appliance is positioned. 

 
 
 

Outdoor Unit 

 

10.

 

Select a location from which noise and outflow air emitted by unit will not inconvenience neighbors. 

11.

 

Select a location where there should be sufficient ventilation. 

12.

 

The inlet and outlet should not be covered. 

13.

 

The location should be able to withstand the full weight and vibration of the outdoor unit and permit 
safe installation. 

14.

 

There should be no danger of flammable gas or corrosive gas leaks. 

15.

 

Be sure that the installation conforms to the installation dimension diagram. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for KFHHP-12-ID

Page 1: ...ditioner OPERATING AND INSTALLATION MANUAL Model KFIHP 09 ID KFHIP 09 OD KFHHP 12 ID KFHHP 12 OD Thank you for selecting Soleus Air To ensure proper operation please read this manual and keep it for f...

Page 2: ...llation 12 13 Install the Indoor Unit 14 Install the Outdoor Unit 15 16 Test Operation and Check after Installation 17 CARE AND MAINTENANCE 18 Care and Maintenance 18 19 Trouble Shooting 20 21 ELECTRI...

Page 3: ...1 Structure and Operation Name of Each Part...

Page 4: ...urself There are no user replaceable parts Please contact your authorized dealer If your air conditioner malfunctions discontinue use and call your authorized dealer Never block the air inlet or outle...

Page 5: ...l to adjust the guide louver and change the direction of air flow Close all doors windows for efficient operation To avoid harm to your pets or plants never direct the airflow at them To avoid damage...

Page 6: ...lbs 24 3 99 2 24 3 99 2 Dimensions W x D x H Indoor unit 30 31 7 48 9 84 32 68 8 86 11 22 Outdoor unit 33 39 12 6 21 26 33 39 12 6 21 26 Connection Pipe Length ft 19 68 Gas additional charge oz ft 0...

Page 7: ...e fan speed runs at Low fan speed The FAN SPEED can be memorized under various modes MODE Button When the unit is turned on press this button The AUTO COOL DRY FAN or HEAT mode can then be selected CL...

Page 8: ...inuously press 1 sec above the tens placed on minute will be decrease 1 in every half second and it goes round with 12 hours SWING Button Press once to have louvers swing oscillate Press twice in one...

Page 9: ...vices When the wireless remote control is lost or broken please use the manual switch It will start in AUTO mode the temperature setting and fan speed cannot be changed Please use a ball point pen or...

Page 10: ...shows the running mode Cooling Heating and Auto and then the air conditioner starts running 3 Press MODE button to select desired running mode 4 Press SWING button to automatically swing and stop whe...

Page 11: ...a location where it is 3 28 feet or more away from other electric appliances such as television audio devices etc 7 Select a location where it is easy to remove and clean the filter 8 Be sure that the...

Page 12: ...nel In fixed circuit there must be electricity leakage protection switch of enough power capacity and air switch with enough space Air switch thermal magnetic breaker can protect the short circuit and...

Page 13: ...11 Installation Dimension Diagram Important Notes The installation must be done by trained and qualified service personnel 212 6 inch 112 6 inch...

Page 14: ...he drainage hose 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 The extended drainage pipe in the room shoul...

Page 15: ...on cables to the N 1 terminal of the terminal board connect the Signal wire to the 2 terminal and connect the live wire to the 3 terminal and connect the grounding wire to the terminal 5 Reassemble th...

Page 16: ...2 Cut off the tailings 1 and tailings 2 or tailings 1 tailings 2 and tailings 3 when routing both the wiring and piping and in Fig 4 are the recommended piping 2 Wrap the piping and wiring and pull th...

Page 17: ...big handle 2 Remove the wire clamp and connect the end of the power connection cord with screws to the wiring terminal board Be sure that the wiring connection is in accordance with the indoor unit s...

Page 18: ...es 1 bar fully tighten Lo handle of manifold valve and stop evacuation Keep it for over 15 minutes to ensure the pressure is constant 4 Remove bonnets of gas and liquid valve 5 Slightly loosen core of...

Page 19: ...here is remote control signal main unit will run at the remote control signal c When turning it to Run position the main unit will run at received remote control order d When turning it to Stop positi...

Page 20: ...it and wipe the dirty places NOTE There are microcomputer components and circuit board on the displayer of the indoor unit front panel never let it dip in the water Cleaning the Air Filters Recommend...

Page 21: ...lters and other parts 2 Turn main power off 3 Clean dust from the outdoor unit Trouble Shooting Warning Don t attempt to repair the air conditioner by yourself it can cause an electric shock or fire P...

Page 22: ...Is the leakage protection switch in operation Is TIMER ON is operation Cooling Heating efficiency is not good Is SET TEMP suitable Is air inlet or outlet obstructed Are air filters dirty Are the wind...

Page 23: ...nusual noise can be heard during operation Air switch or leakage protection switch often shuts down Water is leaking from the unit Electrical lines and power plug are very hot or smoking Wind blowing...

Page 24: ...22 Electrical Schematic Diagram Electrical Schematic Diagram Indoor Unit Please Insert Diagram in here...

Page 25: ...23 Electrical Schematic Diagram Outdoor Unit Please Insert Diagram in here...

Page 26: ...he user abuse misuse neglect accident incorrect power line voltage fire flood or other Acts of God or normal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus main...

Reviews: