background image

OPERATING INSTRUCTIONS 

 

Control Panel  

 

 

 

 

 

Indicator Lights 

 

 

• 

 

Power Indicator Light 

 

The power indicator light will turn on when the unit is plugged in, regardless of whether the unit is operating 
or not. 

• 

 

Tank Full Indicator Light 

 

The tank full indicator light will turn on when the drainage tank is full or positioned incorrectly.  If light is  
on, empty the water out of the drainage tank and make sure the tank is positioned properly. 

• 

 

Power Level Indicator Lights 

  When each light is respectively lighted it indicates that the power level is Medium, High, or Quiet. 

• 

 

Humidity Level Indicator Lights 

 

When each lamp is respectively lighted, it indicates that the current setting for room humidity is 50%, 60%, 
or 70%. When the room humidity reaches the set level, the compressor will shut off. 

• 

 

Continuous Dehumidification Indicator Light 

 

When this light is on, it indicates that the operation is in continuous mode. The unit will continue 
dehumidifying, no matter what the room humidity is. 

 
Button Functions 

 

 

• 

 

Power Button 

Press the button once to start operation, press it again to stop operation. 

• 

 

Power Level Button 

  Each time the button is pressed, the power level changes in the order of: Med, High or Quiet. 

• 

 

Humidity Level Button 

 

Press to set the desired humidity level in the room, which can be set in the order of: 50%, 60%, 70%, 
and continuous.  When the relative humidity of the room is lower then the selected humidity, operation 
will stop automatically. 
When the unit is turned on, the default operation mode is the continuous mode. In this mode, operation 
will continue until the unit is turned off or will stop automatically when the drainage tank is full. 

 

7

Summary of Contents for CFM-25E

Page 1: ...Manual For information or assistance please contact Soleus International 9451 Telstar Ave El Monte CA 91731 Tel 1 888 876 5387 www soleusair com POWERED BY KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE 1 Sales Inquiries 800 934 9194 ...

Page 2: ...moisture from the air to create a more comfortable environment in your home or office This unit can be conveniently moved from room to room within your home and set up in just minutes For easy reference please attach a copy of your sales slip receipt to this page along with the following information that is located on the manufacturers nameplate located on the rear panel of the unit Model Number _...

Page 3: ...eakdown grounding will reduce the risk of electrical shock by providing a path of least resistance for electrical current This dehumidifier is equipped with a cord having an equipment grounding conductor and 3 prong grounded plug The plug must be connected into an outlet that is properly installed and grounded in the accordance with all local codes and ordinances Do not modify the plug provided wi...

Page 4: ...umidistat Different rooms in your home call for different humidity levels and our unit features 3 humidity settings The humidity level feature cycles the unit after the desired humidity level is achieved Magnetic Float Will not become stuck with mineral deposits like other mechanical floats Provides a more accurate water level reading and prevents overflow Quiet Operation When the dehumidifier ope...

Page 5: ...mally SAFETY WARNINGS When using the unit please observe the following safety precautions 1 Unplug the power supply cord before cleaning or storage 2 Do not submerge the unit in water or place the unit close to water 3 Do not set the unit close to heat generating devices or near flammable and dangerous materials 4 Never put your fingers or objects into the intake or discharge ducts 5 Do not sit or...

Page 6: ...PRODUCT DIAGRAM FRONT REAR 6 ...

Page 7: ...umidity reaches the set level the compressor will shut off Continuous Dehumidification Indicator Light When this light is on it indicates that the operation is in continuous mode The unit will continue dehumidifying no matter what the room humidity is Button Functions Power Button Press the button once to start operation press it again to stop operation Power Level Button Each time the button is p...

Page 8: ...tton to select a room humidity level of 50 60 or 70 Power Level Press POWER LEVEL button to choose the desired power level When the indoor temperature is below 59 F or above 95 F the protection device is activated The unit can only operate in HIGH power and the POWER LEVEL button is ineffective 4 Stop operation Press the POWER button to stop dehumidification Never stop the unit by unplugging the p...

Page 9: ...0 minutes before removing the drainage tank If water has dripped wipe it up 9 Fig 1 Fig 2 Fig 3 Continuous Water Drainage The unit features a continuous drainage port Using a commercial hose with an inner diameter of 15 mm the water in the drainage tank can be continuously drained out of the continuous port on the unit NOTE When setting up the equipment for continuous drainage always stop operatio...

Page 10: ...he unit off the floor and move it Avoid rolling the unit if the floor has shag carpeting This can damage the surface of the carpet 2 Tilt it within range of 20 to 30 degrees If you tilt the unit too far you may scratch the floor or water may leak 3 Be careful that the power supply cord does not get pinched under the unit Clearance Maintain the minimum clearance around the dehumidifier when the uni...

Page 11: ... remove dirt If the air filter is exceptionally dirty wash it with warm water and a mild cleanser and dry thoroughly see Fig 8 3 Attach the air filter Insert the lower tabs of the air filter into the main unit and press the air filter in place until you hear the tabs click into place see Fig 9 Fig 7 Fig 8 Fig 9 Storing the Dehumidifier Properly store the unit when it is not being used for an exten...

Page 12: ...ove 95 F or below 36 F The protection device is activated and the unit cannot be started Is the air filter clogged Clean the air filter as instructed under Cleaning the Dehumidifier The dehumidifying function does not work Is the intake duct or discharge duct obstructed Remove the obstruction from the discharge duct or intake duct No air is discharged Is the air filter clogged Clean the air filter...

Page 13: ...cial handling provisions in the instructions 3 Damage to the finish of the case or other appearance parts caused by wear 4 Filter 5 Damage caused by repairs or alterations of the dehumidifier by anyone other than authorized by Soleus International Inc 6 Freight and Insurance cost for the warranty service ALL IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE Y...

Reviews: