background image

(i) CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive

Materials And Vapors.

(j) CAUTION: This unit has an unguarded impeller. Do Not Use In Locations Readily Accessible

To People Or Animals.

(k) All units are suitable for use with solid-state speed control.

The POWERVENT series can be mounted in any orientation, horizontal or vertical, and is suitable for 

numerous types of applications. 

If the installation is made to rigid or flexible ducting, then it is recommended that the correct diameter 

ducting be used to couple to the fan flanges. If it is necessary to bend the duct at the discharge of the 

fan then the bend radius should be as large as possible.

Before installing the product check the following points; (1) the fan impeller turns freely and (2) there 

are no obstructions to the airflow.

All models include a robust mounting bracket, which enables easy and quick installation of the fan. 

See

 Figure (1) 

Installation Diagrams For POWERVENT Duct Fans.

Ductwork connection should be made with duct tape or duct fast-clamps (available through your local 

HVAC wholesale supplier) to ensure a good seal and secure connection.

ELECTRICAL CONNECTION

All POWERVENT series fans operate from a standard 120V 60Hz A.C electrical supply. All wiring must 

be carried out in accordance with National Electrical Code,  and all applicable state and local buildings 

codes. 

Electrical connections should be made in accordance with the electrical wiring diagrams shown in

 

Figure (2)

 Electrical Wiring.

MAINTENANCE

IMPORTANT:  BEFORE  CARRYING  OUT  ANY  MAINTENANCE  OR  SERVICING,  ENSURE  THE 

UNIT IS DISCONNECTED FROM THE MAINS ELECTRICAL SUPPLY.

All POWERVENT series exhaust fans incorporate sealed for life bearings and therefore do not requi

-

re any lubrication. We would recommend inspection of the product at least once every twelve (12) 

months to avoid the excessive accumulation of dust and dirt on the impeller. To inspect the unit dis

-

connect from electrical supply and remove from ducting. If any debris is evident on the impeller clean 

with a damp (not wet) cloth. DO NOT USE any detergents or abrasive materials for cleaning.

4

5

Summary of Contents for powervent PV-100X

Page 1: ...N LIGNE Models 100X 125X 150X 200X 250X 315 315X INSTALLATION AND WIRING INSTRUCTIONS INSTRUCCIONES DE MONTAJE INSTRUCTIONS DE MONTAGE English Español Français READ AND SAVE THESE INSTRUCTIONS LEER Y GUARDAR ESTAS INSTRUCCIONES LIRE ET CONSERVER CES INSTRUCTIONS PV IOM v 4_02 2021 cULus Listed Standards 507 705 ...

Page 2: ...ir los agujeros ranurados en en el soporte con los del ventilador Atornillar y montar el ventilador Placer le ventilateur en faisant coïncider les orifices du support avec ceux du ventilateur puis placer les deux vis de fixation 3 Completely tighten both screws to secure the fan Colocar el otro tornillo y apretar ambos Bien serrer les deux vis de fixation 4 Wire the fan in accordance with the Wiri...

Page 3: ...RICIDAD DE 120V 60Hz Figure 2 Electrical Wiring Conexión Eléctrica Raccordement Electrique Motor without Speed Controller Motor sin regulador de velocidad Moteur sans variateur de vitesse Motor with Speed Controller Motor con regulador de velocidad Moteur avec variateur de vites se IMPORTANT TOUS LES POWERVENT SONT FOURNIS AVEC UN MOTEUR UNIQUEMENT ADAPTE À UNE ALIMENTATION ELECTRIQUE DE 120V 60Hz...

Page 4: ... intended by the manufacturer If you have any questions contact the manufacturer b Before servicing or cleaning the unit switch the power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installat...

Page 5: ...WERVENT Duct Fans Ductwork connection should be made with duct tape or duct fast clamps available through your local HVAC wholesale supplier to ensure a good seal and secure connection ELECTRICAL CONNECTION All POWERVENT series fans operate from a standard 120V 60Hz A C electrical supply All wiring must be carried out in accordance with National Electrical Code and all applicable state and local b...

Page 6: ...ranty Claim with an accompanying description stating the nature of the fault THE FOLLOWING WARRANTIES DO NO APPLY Damages from shipping either concealed or visible Claim must be filed with the carrier Damages resulting from improper wiring or installation Damages caused by acts of nature or resulting from improper consumer procedures such as Im proper Maintenance Misuse Negligence Alteration Abuse...

Page 7: ... OBSERVAR LO SIGUIENTE a Utilizar este aparato solamente en la manera prevista por el fabricante Si tiene dudas con tacte con el fabricante b Antes de manipular o limpiar el aparato desconectarlo del suministro eléctrico a nivel del cuadro de mandos y acerrojar el sistema de desconexión para que no se pueda conectar de nuevo accidentalmente Si no se puede acerrojar el sistema de desconexión fijar ...

Page 8: ...ibremente y 2 que no haya obstrucción al desplazamiento del aire Todos los modelos incorporan un robusto soporte que permite un montaje fácil y rápido del ventila dor Ver Figura 1 los esquemas de montaje de los ventiladores POWERVENT La conexión de los conductos debe hacerse con banda adhesiva o bridas de sujeción disponibles en su almacenista local para asegurar una conexión segura y estanca CONE...

Page 9: ... una nota describiendo la naturaleza del defecto LA GARANTÍA NO CUBRE Daños de transporte que sean internos o visibles La reclamación debe ser presentada al transpor tista Daños debidos a una conexión o instalación incorrecta Daños debidos a catástrofes naturales o como resultado de una utilización incorrecta como manteni miento incorrecto mal uso manipulación incorrecta accidente en el suministro...

Page 10: ...UX PERSONNES PRIERE D OBSERVER LES REGLES SUIVANTES a Utilisez cet appareil uniquement tel que l a prévu le fabricant Si vous avez des questions veuillez contacter le fabricant b Avant de manipuler ou de nettoyer l appareil débranchez le du secteur au niveau du tableau de commandes et verrouillez le système de déconnexion afin d éviter que l appareil ne soit accidentellement reconnecté Si le systè...

Page 11: ...urne librement et 2 qu il n y a pas d obstruction à l écoulement de l air Tous les modèles incorporent un support robuste qui permet un montage facile et rapide du ventila teur Voir Figure 1 les schémas de montage des ventilateurs POWERVENT Le raccordement des conduits doit être réalisé avec une bande adhésive ou des brides de fixation disponibles chez votre fournisseur local afin d assurer un rac...

Page 12: ...nature du défaut LA GARANTIE N EST PAS APPLICABLE Aux dommages de transport cachés ou visibles La réclamation doit être présentée au transporteur Aux dommages dus à des catastrophes naturelles ou résultant d une mauvaise utilisation telle que Entretien incorrecte mauvaise utilisation mauvaise manipulation accident dans la fourniture du courant tension ou courant incorrect Le retrait ou la modifica...

Reviews: