4 - Characteristics and electrical connections 
 

Connecting the cable to the network through a sealed connection box. 

Wire H05VV-F-5G1 

Length 1.2 m 

Power supply : 
Single phase 230-50Hz 
Electrical protection: 
3A   
Maximum power: 
230 W 
Max. ambient temperature: 
50ºC 
Max. temperature of flow:   
45ºC 

Not  commissioning  the  central  until  all  the  ducts  are  all  completely  fitted  (Air  inlet, 
retaining grille or roof outlet, supply and extraction outlets, ducts and filters fitted)  
When  started,  the  central  IDEO  automatically  adapts  to the  specific characteristics  of 
each installation. If any component is missing or badly fitted, normal operation may be 
affected. 

Connection box 

Electrical panel 

Summary of Contents for IDEO2 325 Ecowatt

Page 1: ...2 IDEO 325 Ecowatt Installation manual and comissioning EN ...

Page 2: ... working never stop the ventilation system 1 General information 2 Technical information 3 Installation 4 Characteristics and electrical connections 5 Control of the IDEO 6 Commissioning of the IDEO 7 Change of the communication channel 8 Access to error menu Summary ...

Page 3: ... will not be held liable for damage produced by Misuse Normal wear and tear of components Non observance of the instructions contained in this manual regarding safety use and start up The use of components not supplied by Soler Palau 1 3 Safety General safety rules After installation there should be no risk with the security health or environmental hazards in compliance with EC regulations This is...

Page 4: ...IDEO2 325 Ecowatt efficiency can reach 95 Condensation appears equally at the time of exchange with the introduction of new air It is collected in the condensate container which must be connected to the drain Avoiding the heat exchanger the system bypass 100 IDEO allows the introduction of fresh air at night without it being heated by contact with hot air accumulated in the house during the day Th...

Page 5: ...e fresh air in the night without being warmed by the warm air accumulated in the house during the day This system works automatically or can be forced manually See chapter 5 2 Function Without By pass Function With By pass New fresh air inlet On this spigot is connected to the outside air inlet Be sure to position the fresh air intake wall or roof at a sufficient distance from any area with high p...

Page 6: ...2 3 Dimensional characteristics 2 3 a Central unit Weight 51 Kg Programmable module Boost 2 3 b Remote controls ...

Page 7: ...mended to locate IDEO in heated house space Otherwise it will be necessary to insulate the condensate drain 3 Installation 3 1 On a vertical wall 300 Uninsulated duct Insulated duct Insulated duct Ducts should be insulated and fitted perfectly ...

Page 8: ...3 3 Hubcap for ducts Optional 4 x 4 x ...

Page 9: ...50 Aire intake roof D150 Kitchen Toilets Living room Bedrooms Or Or Or CPR or CT 150 BDO or BOAP 125 BDO or TPM 80 Plenum 4 or 8 spigots Plenum 7 spigots In the case of use of flexible duct insulated it is imperative to stretch it Or Air intake PAQS150 ...

Page 10: ...0 BDOP 125 BDOP D80 RD80 BAR Air intake D150 PAF 150 Air intake roof D150 BDOP D80 RD80 Bedrooms Living room BDOP 125 Kitchen Toilets Or Or Or In the case of use of flexible duct insulated it is imperative to stretch it Or Air intake PAQS150 ...

Page 11: ...nt temperature 50ºC Max temperature of flow 45ºC Not commissioning the central until all the ducts are all completely fitted Air inlet retaining grille or roof outlet supply and extraction outlets ducts and filters fitted When started the central IDEO automatically adapts to the specific characteristics of each installation If any component is missing or badly fitted normal operation may be affect...

Page 12: ... for a few seconds to notify the battery level The button has a CR2032 battery The programming module is located on the front of the machine This remote control can also be located on a wall or placed in a support of the house table furniture The remote control module is in permanent communication with the IDEO central unit Service life with normal use consultation by the user 5 times a day on ave...

Page 13: ... Absence mode 9 Transmission reception level 10 Battery level 11 Default mode 12 Change filter 13 Energy saving in kW per month kWh m 14 Instant energy saving 15 Outdoor temperature in degrees centigrade in the fresh air inlet 16 Indoor temperature in degrees centigrade on the remote control 17 Value display Hour flow kilowatts 18 Validation key 19 Move right key 20 Move left key 5 6 7 8 9 4 10 11...

Page 14: ...ng keys 19 and 20 Validate with key 18 The pictogram 3 of day day flashes Choose No of day day depending on your choice of programming Settings airflow of 90 m3 h minimum airflow to 325m3 h maximum airflow according to size of accommodation see tables below Note The airflow of the supply fan is automatically adjusted with the extract airflow Minimum airflow Navigating with buttons 19 or 20 until p...

Page 15: ...Manual This mode allows you to choose depending on your lifestyle periods of passage Max Airflow 1 hour for programming and in the limit of 3 programming per day Schedules may be different for each day of the week Start Finish Start Finish Start Finish Monday 6h30 7h30 19h30 20h30 Tuesday 6h30 7h30 19h30 20h30 Wednesday 6h30 7h30 19h30 20h30 Thursday 6h30 7h30 19h30 20h30 Friday 6h30 7h30 19h30 20...

Page 16: ...disable bypass forced To do this Navigate with the buttons 19 or 20 until 6 pictogram bypass Select with key 18 Select OFF using keys 19 or 20 Confirm with 18 Example of programming DAY 1 Monday T1 start 6 30h end 7 30h T2 no programming T3 start 19 30h pm end 20 30 p m Navigate with the arrow keys until 19 or 20 until pictogram 2 Select Man Confirm by pressing 18 Confirm by pressing again the but...

Page 17: ...r more filters are dirty and should be cleaned or changed F1 Filters on the supply air F2 Filters on the extract air The duration of the fouling up can change depending on the conditions of use and the area in which your home is located what level of outdoor pollution is industrial road or vegetable Generally the duration change between 6 and 12 months Warning If this icon appears at the start or ...

Page 18: ...n of the electrical protector 3A 2 Switch on the IDEO 3 Set the time and the day 4 Set the minimum and maximum airflow 5 Choice of mode auto 1 auto 2 manual or boost 6 Select the bypass mode 7 Set the type of external switch if installed NO for Normally Open and NC for Normally Closed see Chapter 6 1 8 Check the transmission reception level between the remote control and the IDEO In the case of a ...

Page 19: ...nd IDEO Factory setting Channel 0 Up to 64 from 0 to 63 To modify the channel see Chapter 2 9 6 1 Access to installation menu Accessing to this menu allows to check and adjust the IDEO s parameters of each installation Reset of the factory settings Identification of software version remote control 3 seconds To access to the menu Parameter blocking airflows time etc OFF Parameters that can be modif...

Page 20: ...6 micro switches 3 seconds 0 CHAn 15 7 2 On the boost see coding on following page Remove the battery 63 Or 7 3 On the central module Before taking any action switch off the unit For taking account of the change of channel the module must not be switched on Open the front six screws Take out the central module 1 2 ...

Page 21: ...nly be accessed when the spanner icon is present 1 To access to the menu 3 seconds 1 Error icon E No error E0 Communication error E1 Supply motor error E2 Extract motor error E3 By pass error E4 Channel error E5 Error of the air intake temperature sensor E6 Error of the extract temperature sensor E7 Error of the air discharge temperature sensor ...

Page 22: ......

Page 23: ......

Page 24: ...S P Sistemas de Ventilación S L U C Llevant 4 08150 Parets del Vallès Barcelona Tel 34 93 571 93 00 Fax 34 93 571 93 01 www solerpalau com Ref 9023019302 01 ...

Reviews: