Recommendation for the battery:
Charge the LR-BST-25 battery for 12 hours the day before installation.
Power transformer connection
Solar panel connection
230V
230V
24V
24V
Electrical connection recommendations
for the power transformer:
• Use the power transformer supplied with the product.
• Connect the 230Vac input of the transformer to the lectrical network by protecting it
with a 2A circuit breaker.
• Connect the 24Vdc output of the transformer to the LR-BST-25 using a H05RN-F
2x0.75mm² jacketed cable.
• Place the trans circuit breaker assembly in a Class II electrical box.