The suitable positions are as follows:

The highest hole (tip) is for areas 25-35° latitude (inclination 25°)
The middle hole is for areas 30-40° latitude (inclination 30°)
The lowest hole for areas 35-50° latitude. (inclination 35°)

b) If however maximum efficiency is of no concern for the whole year and enhanced efficiency is
required  during  the  summer  (which  will  result  in  decreased  efficiency  during  the  winter)  move
the support points A (photo 2) one hole higher than the proper place which is described earlier.
This  can  be  applied  in  the  case  of  hotel  installations,  specifically  for  hotels  which  are  fully
booked during the summer and are either closed or have very few guests during the winter.

If  on  the  other  hand  enhanced  efficiency  is  required  during  the  winter  (resulting  in  decreased
efficiency during the summer) then the support points A are moved one hole below the proper
hole.

After adjusting the product’s inclination, the collector must have a south facing position if your
location is in the northern hemisphere or a north facing position if your location is in the southern
hemisphere.