1. CHLORINE FROM CHEMICALS OR SALT SYSTEMS ARE NOT A PROBLEM AND THE SYSTEM MAY 
BE STARTED WHILE USING CHLORINE.

2. Test pool water and adjust pH, total alkalinity and calcium hardness levels before starting system.  See 
Table below.

POOL WATER PREPARATION

OPERATION

WARNING:  DO  NOT  ATTEMPT  TO 
OPEN THE POWER SUPPLY FOR ANY 
REASON.    IT  IS  SEALED  AND  NOT 
DESIGNED TO BE REPAIRED IN THE 
FIELD.    A  DEFECTIVE  OR  NON 
FUNCTIONING  POWER  SUPPLY  IS 
REPLACED WITH A NEW UNIT ONLY.

- Steady Blue LED = system has power and is 
operating normally
- Flashing Blue LED = no flow to chamber.  This 
could  be  caused  by  the  pool  pump  losing  its 
prime or from blockage in the plumbing. Check 
water flow through system.

Note:

 

The  flow  is  determined  using  a 

temperature sensor. Therefore, it may take a 
few  minutes  to  recognize  that  flow  has 
stopped when the system turns off. This is 
not harmful to the Precision chamber.

- Steady Red LED = system error.   This means 
an  error  has  occurred  in  the  power  supply.  
Please go to www.solaxx.com to create an RMA 
form which will be answered within 24 hours or 
next business day to resolve this issue.

System On 
(Flashing - No Flow)

Check Manual 
or Our Website

8

Summary of Contents for Precision UV

Page 1: ...Installation and Operating Instructions PRECISION PRECISION www solaxx com PRECISION PRECISION AUTOMATIC REGULATOR FLOW...

Page 2: ...nit WARNING ELECTRICSHOCK DisconnectallACpowerduringinstallationorperforminganyservicework CAUTION Topreventpossible reorelectricalshock useonlyreplacementlampspeci edbythemanufacturer CAUTION Donotus...

Page 3: ...e quality of drinking water A microscopic residual of chlorine 5 1 0 ppm is recommended for use with this system as a supplemental source of disinfection For best results the pool pump should run at l...

Page 4: ...ally diverted into the UV chamber at the proper ow rates Restriction to the plumbing is nominal when the manifold is inserted into the plumbing and is comparable to adding a heater to the pool See bel...

Page 5: ...LHEALTH A Unthread and remove the end cap with the wire attached from the end of the UV chamber by rst loosening the small black plastic nut then the larger black nut to pull out plug B Pull gently un...

Page 6: ...ing power supply 2 Mount the aluminum bracket rst on a vertical surface at a height of approximately ve 5 feet above the ground using the screws provided with the spacers against wall to allow air ow...

Page 7: ...2 inch UL514B 5 Wires 6 Items 3 4 5 Not supplied INSTALLATION 1 2 3 4 5 Ground L1 L2 Line Pump Power Supply Box 240V Install Ground L1 N Line Pump Power Supply Box 110V Install Wires to be connected t...

Page 8: ...IELD A DEFECTIVE OR NON FUNCTIONING POWER SUPPLY IS REPLACED WITHANEW UNIT ONLY Steady Blue LED system has power and is operating normally Flashing Blue LED no ow to chamber This could be caused by th...

Page 9: ...the power supply which is mounted to the wall and slide up off of mounting bracket C Unthread the union nuts and remove the entire manifold from the pipe and store safely inside D Cover opening in pi...

Page 10: ...TTING OILS FROM HANDS ON THE LAMP SKIN OILS ATTACH TO THE LAMP AND SHORTEN ITS EFFECTIVE LIFE IF LAMPISTOUCHED WIPE CLEAN WITHASOFTCLOTHAND RUBBINGALCOHOL CLEANING THE QUARTZ SLEEVE The quartz sleeve...

Page 11: ...n any respect including but not limited to the use of parts other than genuine manufacturer parts If this System is installed for use on non residential pools or pools bigger than 35 000 gallons this...

Page 12: ...MAN6000 12 17 PRECISION PRECISION www solaxx com...

Reviews: