Installation

4.1 

Installation Prerequisites

Make sure that the installation location meets the following conditions:

Ÿ

The building is designed to withstand earthquakes

Ÿ

The location is far away from the sea, to avoid salt water and humidity

Ÿ

The floor is flat and level

Ÿ

There are no flammable or explosive materials nearby

Ÿ

The ambience is shady and cool, keep away from heat and avoid direct 
sunlight.

Ÿ

The temperature and humidity stays at a constant level.

Ÿ

There is minimal dust and dirt in the area.

Ÿ

There is no corrosive gases present, including ammonia and acid vapor.

Ÿ

The ambient temperature is within the range from 0°C to 55°C, and the 
optimal ambient temperature is between 15

 and 35°C.

NOTE!

If the ambient temperature is outside the operating range, the battery pack 
stops operating to protect itself. The optimal temperature range for the battery 
pack to operate is 15°C to 35°C. Frequent exposure to harsh temperatures may 
deteriorate the performance and lifetime of the battery pack.

4.2 

Safety Gear

Installation and maintenance personnel must operate according to applicable 
federal, state and local regulations as well as the industry standards regarding the 
product installation personnel shall wear safety gears, etc. in order to avoid short 
circuit and personal injury.

Insulated gloves

Safety goggles

Safety shoes

4. Installation

12

13

4. Installation

4.3 

Tools

These tools are required to install the T-BAT system.

Torque screw driver

Phillips-screw driver

Socket nut wrench

Phillips-head screw driver

Flat-head screw driver

Torque wrench

Tape measure

Drill

Pencil or Marker

4.4 

 Installation

4.4.1  

Check for Transport Damage

Make sure the battery is intact during transportation. If there are some visible 
damages, such as cracks, please contact your dealer immediately.

4.4.2  

Unpacking

Unpacking the battery package by cutting the packing tape and make sure the 
battery packs and the relevant items are complete. See package items on section 
4.4.3, please check the packing list carefully, if there's any item missing, please 
contact SolaX or your distributer directly.

CAUTION!

According to regional regulations, several people may be required for 
moving equipment.

WARNING!

Please strictly follow the installation steps. SolaX will not answer for any 
hurting or loss arising by incorrectly assembling and operation.

NOTE!

The Triple Power battery pack is rated at IP55 and thus can be installed 
outdoors as well as indoors. However, if installed outdoors, do not allow the 
battery pack to be exposed to direct sunlight and moisture.

Summary of Contents for Triple Power T-BAT PACK-HV

Page 1: ...td SolaX Power Co Ltd Any corporation or individual should not plagiarize partitially or fully copy including software etc and no reproduction or distribution of it in any form or by any means All rig...

Page 2: ...AGED BATTERIES 5 2 3 QUALIFIED INSTALLER 6 3 PRODUCT INTRODUCTION 7 3 1 PRODUCT OVERVIEW 7 3 1 1 DIMENSION AND WEIGHT 7 3 1 2 APPEARANCE 8 3 2 BASIC FEATURES 10 3 2 1 FEATURES 10 3 2 2 CERTIFICATIONS...

Page 3: ...indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTE NOTE provides tips that are valuable for the optimal operation of your product 4 5 CABLE CONNECTION...

Page 4: ...battery pack T BAT SYS HV can be used only in the household energy field It is not allowed to be used in other industries such as the medical equipment and automotive application WARNING Please don t...

Page 5: ...eyes with flowing water for 15 minutes and seek medical attention immediately Dermal contact Wash the affected area thoroughly with soap and water and seek medical attention immediately Ingestion Indu...

Page 6: ...ices Knowledge of and adherence to this manual and all safety precautions and best practices 6 7 3 Product Introduction 3 1 Product Overview For safety reasons installers are responsible for familiari...

Page 7: ...85 Connector to RS485 I of next battery pack Power Connector to XPLUG of next battery pack or to of the same pack Air valve BAT BAT CAN YPLUG RS485 II XPLUG RS485 I YPLUG RS485 II Power Connector to o...

Page 8: ...3 3 Specifications 3 3 1 T BAT SYS HV Configuration List 3 3 2 Performance Model Battery Pack Energy kWh Voltage V No 1 2 3 4 T BAT H 5 8 T BAT H 11 5 T BAT H 17 3 T BAT H 23 0 T BAT H 5 8 1 T BAT H 5...

Page 9: ...product installation personnel shall wear safety gears etc in order to avoid short circuit and personal injury Insulated gloves Safety goggles Safety shoes 4 Installation 12 13 4 Installation 4 3 Too...

Page 10: ...ver plate2 Wall bracket M5 screw Expansion bolt Ring terminal for grounding Power cable disassembling tool Quantity 1 1 1 1 2 8 2 1 1 5 2 1 L HV11550 Quantity Object A1 B1 C1 D1 E1 F1 G1 H1 I1 J1 Desc...

Page 11: ...are deep enough at least 50mm for installing and tightening the expansion bolts J or I1 Install the expansion bolts in the wall and screw the bracket by using the wrench Step 2 Match the battery with...

Page 12: ...3 battery packs 1 Connect for T BAT H 5 8 or for HV11550 on the right side to on the left side of the next battery pack 2 Connect YPLUG for T BAT H 5 8 or for HV11550 on the right side to XPLUG on th...

Page 13: ...p is going to connect power lines between Inverter and T BAT system The default length of power lines are 2 meters so customers can appropriately cut the cable accroding to the actual installation env...

Page 14: ...system is not turned o otherwise there will be an arc discharge that could cause serious injury CAUTION Disassembling Power Line on BAT BAT XPLUG port 22 23 4 Installation 4 Installation YPLUG RS485...

Page 15: ...with an orange stripe 2 Orange 3 White with a green stripe 4 Blue 5 White with a blue stripe 6 Green 7 White with a brown stripe 8 Brown Sequence 1 2 3 4 5 6 7 8 CAN GND CAN_H CAN_L A1 B1 4 5 4 Conne...

Page 16: ...6 Overall Installation It is recommended to protect the cables by using corrugated pipe For T BAT H 5 8 1 Connect all the cables on the left side of T BAT H 5 8 2 Get the cables through the corrugate...

Page 17: ...ert the series connected plug at and YPLUG on the right side of last battery pack to make a complete circuit CAUTION One T BAT system is allowed to install one T BAT H 5 8 plus at most three battery p...

Page 18: ...AT H 5 8 5 Matching T BAT H 5 8 1 HV11550 6 Matching T BAT H 5 8 2 HV11550 7 Matching T BAT H 5 8 3 HV11550 Black start configuration 5 Commissioning 5 Commissioning NOTE When powering on the BMS the...

Page 19: ...her charging nor discharging the indicator lights off When the battery pack is charging part of the Blue LED is flashing with the frequency of light on for 0 5s light off for 0 5s and part of the Blue...

Page 20: ...tem A warning state is triggered when a condition such as voltage or temperature is beyond the design limitations The T BAT system s BMS periodically reports its operating state to the inverter When t...

Page 21: ...tor XPLUG of the BMS 2 If the rst step still does not work please contact SolaX after sales service or your distributor directly BMS_SelfChk_Fault BMS selfcheck fault Please contact SolaX after sales...

Page 22: ...er Disconnect the series wiring terminal on the ended battery Disconnect the other cables 7 2 Packing Please pack the BMS and battery packs with the original packaging If it is no longer available you...

Reviews: