SolaX Power T-BAT H11.2 Manual Download Page 24

STATUS INDICATOR 

BMS Status Indicator: 

Charge 

Discharge 

60% Power

 

Summary of Contents for T-BAT H11.2

Page 1: ...Triple Power High Voltage Storage System www solaxpower com...

Page 2: ...CONTENTS 1 3 4 OVERVIEW INTRODUCTION CERTIFICATION INSTALLATION STATUS INDICATOR TROUBLESHOOTING...

Page 3: ...ElectricMeter Bidirectional Surge Arrestor Fuse DCBreaker Surge Arrestor Fuse DCBreaker EPS Load Commo nLoad DC Breaker AC Breaker Contactor Battery System Photovoltaicsystem consist of Solar cell mo...

Page 4: ...Flexible Scheme 8 type of system can be chose Quality Assurance Passed a series of certifications eg TUV IEC 62619 OVERVIEW Easy Installation Simple wire connection and fast installation...

Page 5: ...ge Cycle Life 6000 Hardware Secondary Protection Classified Protection IP55 Safety Reliable Little Space Taking Two Installation Methods Floor Mounting Wall Mounting For Single Phase Storage Inverter...

Page 6: ...y Module Energy KWh Voltage V 1 T BAT H4 0 MC0500x1 HV10040X1 4 85 118 2 T BAT H8 0 MC0500x1 HV10040X2 8 170 236 3 T BAT H12 0 MC0500x1 HV10040X3 12 255 354 4 T BAT H16 0 MC0500x1 HV10040X4 16 340 472...

Page 7: ...rrent A 30 30 30 Recommend Charge Discharge Current A 25 25 25 Standard Power kW 2 5 2 5 Maximum Power kW 3 3 Faradic Charge Efficiency 25 77 99 Battery Round trip Efficiency C 3 25 77 95 Expected Lif...

Page 8: ...CTION BMS Port Port Lable Description A Breather Valve B XPLUG Power Port Connect with battery module C RS485 RS485 Communication Port D DIP DIP Switch E ON OFF Air Switch F POWER Power Switch G CAN C...

Page 9: ...Port Port Lable Description A XPLUG Power Port Connect with the next one battery module YPLUG port B RS485 I RS485 communication port 1 Connection with battery module s communication port C GND Connec...

Page 10: ...Battery pack safety CE FCC RCM TUV IEC 62619 UL 1973 Battery cell safety UL 1642 UN number UN 3480 Hazardous materials classification Class 9 UN transportation testing requirements UN 38 3 Internatio...

Page 11: ...INSTALLATION Design Sketch...

Page 12: ...INSTALLATION Complete Installation Drawing...

Page 13: ...upposed to estimate the GND wire first according to their actual installation site Then connect GND wire with battery module Then start installing floor mounting or Wall mounting Lastly connect power...

Page 14: ...ION 2 Power Line Connection a Connect Power Line Length 120mm between BMS and Battery Module BMS XPLUG with Slave Controller XPLUG BMS Master Controller Slave Controller Battery Module Slave Controlle...

Page 15: ...into this batterymodule sYPLUG port when finishing the Power line Communication line connection so that can make a completeelectric loop Note If using 2 4 batterymodules you should use power line Len...

Page 16: ...INSTALLATION 2 Power Line Connection Actual Connection Diagram...

Page 17: ...BMS RS485 port and Battery Module sRS485I port then tighten the plastic nut If more than one batterymodule 2 4 Battery Modules after finishing the communication connectionbetween BMS and First batter...

Page 18: ...INSTALLATION 3 Communication Line Connection CAN Communication Connecting CAN Communication Line Length 2mm between BMS CAN Port and Inverter CAN Port...

Page 19: ...INSTALLATION 4 GND Connection THIS IS MANDATORY REQUIREMENT Using 10AWG GND line to connect GND Port between BMS and Battery Module then connect with inverter s GND Port in the end...

Page 20: ...INSTALLATION 5 Charge Line Connection Connectto Inverter Using Power Line Length 2m to complete connections between Inverter and BMS...

Page 21: ...INSTALLATION 5 Communication Line Connection Connectto BMS Using Power Line Length 2m to complete connections between Inverter and BMS...

Page 22: ...N 6 Commission a Set theAir Switch to ON b Turn on the Power Switch Note Please make sure the interval time at least exceeding 10 seconds before next time to press button c Turn the Power Switch of th...

Page 23: ...r No Mode Status of BMS 1 Active Green LED flashes once every 5s 2 Protection Yellow LED flashes once every 5s 3 Fault Red LED flashes once every 5s 4 Configuring Green LED keeps on 5 Upgrade for mast...

Page 24: ...STATUS INDICATOR BMS Status Indicator Charge Discharge 60 Power...

Page 25: ...Module 1 Active Green LED flashes once every 5s 2 Warning Yellow LED flashes once every 5s 3 Protection Red LED flashes once every 5s 4 Configuring Green LED keeps on 5 Upgrade for master module Gree...

Page 26: ...service or your distributor directly BMS_TemHigh Battery over temperature Wait till the temperature of cells go back to the normal state BMS_TemLow Battery under temperature Wait till the temperature...

Page 27: ...Thank you...