8
6
EPS Box(UK)
Quick Installation Guide
Tools
Before you start, get the following tolls ready.
EPS Box is a manual changeover switch which is
compatible with SolaX hybrid inverter. Configured
with EPS Box, customers just need to connect
several wires between inverter and EPS Box.
Please read this guide carefully before use.
5.1 Wires making
Wires below are needed
before installation.
Use the diagonal plier to trip
15mm of insulation from one
side of the wire as below.
Insert this end of wire into
cold pressed terminal and
tighten it.
GND wire*1
12AWG
w
ire
s*2pcs
12AWG
Open the box by the screwdriver, and take the breaker down.
Open the tap hole, and then insert SUPPLY-L wire and SUPPLY-N wire into the ports of the
contactor(2&6) through the hole.
5.2 SUPPLY-wires connection
SUPPLY-L wire
SUPPLY-N wire
Open the box
Connect wires
01
02
GND
4
2
Screwdriver
II
Introduction
I
III
V
12mm
15mm
12mm
Mounting
IV
Diagonals plier
Box shell-GND
The wires marked 1,2,3 and 4 are
already prepared in the EPS BOX.
2AWG
w
ire
s*4pcs
EPS Box
EPS Load
2AWG
1
3
4
SUPPLY-L wire
——
2
SUPPLY-Nwire
——
6
SUPPLY-L
/
N
wire
~
2AWG
2
6
6
2