background image

8

6

EPS Box(UK)

Quick Installation Guide

Tools

 Before you start, get the following tolls ready.

EPS Box is a manual changeover switch which is   
compatible with SolaX hybrid inverter. Configured 
with EPS Box, customers just need to connect 
several wires between inverter and EPS Box. 

Please read this guide carefully before use.

5.1 Wires making

Wires below are needed 
before installation.

Use the diagonal plier to trip 
15mm of insulation from one 
side of the wire as below.

Insert this end of wire into 
cold pressed terminal and 
tighten it.

GND wire*1

12AWG 

w

ire

s*2pcs

12AWG

Open the box by the screwdriver, and take the breaker down.

Open the tap hole, and then insert SUPPLY-L wire and SUPPLY-N wire into the ports of the 
contactor(2&6) through the hole.

5.2 SUPPLY-wires connection

 SUPPLY-L wire

 SUPPLY-N wire

Open the box

Connect wires

01

02

GND

4

2

Screwdriver

II

Introduction

I

III

V

12mm

15mm

12mm

Mounting

IV

Diagonals plier

Box shell-GND

The wires marked 1,2,3 and 4 are 
already prepared in the  EPS BOX.

2AWG 

w

ire

s*4pcs

 EPS Box

EPS Load

2AWG

1

3

4

SUPPLY-L wire

 ——

 

SUPPLY-Nwire

 ——

 6

SUPPLY-L

/

N

wire

~

2AWG

2

6

6

2