18
SOLATHERM
reserves the right to modify characteristics of the products or their accessories and components without prior notice.
FITTING No.1
SAFETY NON-RETURN
VALVE No.9
LEFT FRONTAL
VIEW OF THE
SOLAR SYSTEM
BALL VALVE ½’’MALE X ½’’
FEMALE No.10
(IF
INCLUDED IN THE KIT) IS
INSTALLED RIGHT AFTER
THE SAFETY NON-RETURN
VALVE.
The
THERMOSTATIC MIXING
VALVE No. 16
(OPTIONAL) is
placed after the HOT WATER
OUTELT as per instructions
included in the mixing valve,
in order to limit the hot water
temperature delivered to the
Tap and avoid burning. It is
recommended that the hot
water delivered at the Tap is
limited to 50°C.
FITTING No. 4
COPPER TUBE &
INSULATION
No.13
FITTING No. 2
FITTING No. 6
COLD INLET
FITTING No. 3
FITTING No. 8
Attach it after close loop
is filled with heat transfer medium
(see “close loop filling”
in this manual)
ATTENTION
:
when placing the brass fittings
with mechanical tightening on the Ø22
copper tubes of the collector do it carefully
in order not to rotate the copper tuber. If
the copper tube is rotated, it can cause
damage to the absorber and break the
wildings between the vertical tubes (risers)
with the Ø22 tubes (headers), which will not
be covered by the warranty. Opposite force
is necessary to avoid damage!