background image

SÓLAS

 CONTEMPORARY FIRE 

4

LOG SET INSTALLATION

STEP 1
 Install the logset burner within the firebox by lowering 

the burner into the firebox (while keeping the burner 

pressed toward the right side of the firebox) then 

sliding the burner left towards the center of the firebox 

to engage the burner orifice as shown in figure 10. 

Confirm that the burner inlet tube has engaged the 

burner orifice. (Figure 10)

STEP 2
Secure the burner using the (4) #10 sheet metal screws 

set aside from steps 4 & 5

STEP 3
Secure the valve bracket using the (2) #10 sheet metal 

screws set aside from steps 1 & 2.

STEP 4
Install the 3-rock cluster on the 2 pins located just right 

of the pilot. (Figure 11) 

Figure 10

Figure 11

> Start HERE if the ONE6 Wall-Mount was originally ordered with a Log Set Burner

NOTE: The log set burner can be configured for either 

Natural Gas or Propane by installing or removing a collar 

on the burner venturi. Figure 8 shows the venturi inlet with 

the collar installed on a burner configured for Natural Gas. 

Figure 9 shows the venturi inlet with the collar removed 

from a burner configured for Propane. THIS VENTURI IS 

NOT ADJUSTABLE. If you need to convert your burner 

from Propane to Natural Gas or vice-versa, please order 

the appropriate conversion kit for your appliance.

INTALLATION OF BIRCH LOG SET

Collar OFF for LP

Collar ON for NG

Figure 8

Figure 9