Module clamps

Module clamps

areas approved for fastening

substructure

Min. clamp surface area: 8 x 40 mm

Min. clamp surface area: 8 x 40 mm

24

8

24

8

24

8

24

8

requires a central, round or linear support 

on the lower frame side (central support)

1.000

120

135

120

135

135

120

135

120

Max. permitted pressure load to the module: 2.400 N/m²

Max. permitted pressure load to the module: 2.400 N/m²

Insertion system

Max. permitted pressure load to the module: 3.600 N/m²

It is not permitted to use SOLARWATT solar modules as overhead glazing. For roof installati-
on, these solar modules may only be installed over a fi re-resistant roof covering.

NOTE

Additional system-specifi c load limits can be found in the download area 

at www.solarwatt.com.

Under mechanical load, no contact between solar glass and hard materials (eg. metal, glass) 
may occur. The drainage holes in the module frame must not be covered, as it could cause 
frost damage on the module frame. Do not place any plug connectors in the frame.

NOTE

SUBJECT TO CHANGE | © 2019 SOLARWATT GMBH | AZ-TM-PMS-1584 | REV 001 | STATUS: 01/2019 | PAGE 17

Summary of Contents for BLACK 60M STYLE

Page 1: ...ng aerial systems EN 62305 Lightning protection EN 62446 Grid coupled photovoltaic systems IEC 60364 Erection of low voltage systems EXCLUSION OF LIABILITY The warranty terms available at www solarwat...

Page 2: ...valid in the relevant country when plan ning setting up and operating grid connec ted PV systems For information on additional requirements please contact the responsible local authorities and the net...

Page 3: ...ind and snow loads as well as the weight of the solar modules The instructions from the installation system manu facturer must also be complied with No mecha nical stresses from the actual building e...

Page 4: ...dule heats up during operation Ensure that there is sufficient rear ventilation to avoid reductions in yield Also ensure that no flammable gases can escape or accumu late close by NOTE In regions with...

Page 5: ...ws Module clamps areas approved for fastening substructure Only use the holes longhole14x9mm provided in the frame Min clamp surface area 8 x 40 mm 860 245 245 245 245 Max permitted pressure load to t...

Page 6: ...module 3 600 N m It is not permitted to use SOLARWATT solar modules as overhead glazing For roof installati on these solar modules may only be installed over a fire resistant roof covering NOTE Additi...

Page 7: ...aximum system voltage as listed in applicable data sheet The maximum num ber of solar modules installed parallel without string fuse is two Please comply with the value specified in the data sheet for...

Page 8: ...g cable lug with ground cable Toothed locked washer Module frame with hole for grounding 4 0 mm Spring washer Nut It is advisable to install lightening protection in exposed locations The solar module...

Page 9: ...ctive is nati onally oriented meaning that each EU Member State has its own legal regulations and practical handling for the sale and return of PV modules Contact us by e mail at info solarwatt com an...

Reviews: