Module clamps
Module clamps
areas approved for fastening
substructure
Min. clamp surface area: 8 x 40 mm
Min. clamp surface area: 8 x 40 mm
24
8
24
8
24
8
24
8
requires a central, round or linear support
on the lower frame side (central support)
1.000
120
135
120
135
135
120
135
120
Max. permitted pressure load to the module: 2.400 N/m²
Max. permitted pressure load to the module: 2.400 N/m²
Insertion system
Max. permitted pressure load to the module: 3.600 N/m²
It is not permitted to use SOLARWATT solar modules as overhead glazing. For roof installati-
on, these solar modules may only be installed over a fi re-resistant roof covering.
NOTE
Additional system-specifi c load limits can be found in the download area
at www.solarwatt.com.
Under mechanical load, no contact between solar glass and hard materials (eg. metal, glass)
may occur. The drainage holes in the module frame must not be covered, as it could cause
frost damage on the module frame. Do not place any plug connectors in the frame.
NOTE
SUBJECT TO CHANGE | © 2019 SOLARWATT GMBH | AZ-TM-PMS-1584 | REV 001 | STATUS: 01/2019 | PAGE 17