Part No. 502621 Issue 10
22
7.0: Specifications
7.0: Specifications
7.1: Electrical
Parameter
Value
Comments
Power Supply
Typical Voltage / Current
24 VDC at 55 mA
Voltage Range
10 to 30 VDC
Current Range
140 mA at 10 V to 50 mA at 30 V
Transducer Excitation
Energising Voltage
3 Vrms nominal
see note 1
Energising Frequency
2.5 kHz (Lo) or 5 kHz (Hi) nominal
10 kHz (Lo) or 13 kHz (Hi)
link selectable
Half-Bridge version only
Energising Current
30 mA max.
Transducer Signal Input
Input Signal Range Standard
400 to 2500 mV FR
6 gain ranges (applies to LVDT only)
Special
DIV2 2500 to 500 mV FR
x2 150 to 400 mV FR
x4 55 to 150 mV FR
see note 2
Input Load Resistance
2, 10, 10 kΩ
link selectable
Options
Forward and Reverse
LVDT Input
Half-Bridge Input
link selectable
standard
special plug wiring or half-bridge
version only