Solaronics SIGB Installation, Use & Maintenance Manual Download Page 21

Digitális változók / Digital variables

Cím / 

Address

Név /Name

Mért. 

egys.

Alap-
beáll.

Hozzáférés 

/Access

Leírás / Description

46

DI1 állapota / DI1 Status

R

Dig.bemenet 1 értéke / Actual Value of digital input 1

47

DI2 állapota / DI2 Status

R

Dig.bemenet 2 értéke / Actual Value of digital input 2

48

DI3 állapota / DI3 Status

R

Dig.bemenet 3 értéke / Actual Value of digital input 3

49

DI4 állapota / DI4 Status

R

Dig.bemenet 4 értéke / Actual Value of digital input 4

50

DI5 állapota / DI5 Status

R

Dig.bemenet 5 értéke / Actual Value of digital input 5

51

DI6 állapota / DI6 Status

R

Dig.bemenet 6 értéke / Actual Value of digital input 6

52

DI7 állapota / DI7 Status

R

Dig.bemenet 7 értéke / Actual Value of digital input 7

53

DI8 állapota / DI8 Status

R

Dig.bemenet 8 értéke / Actual Value of digital input 8

54

DI9 állapota / DI9 Status

R

Dig.bemenet 9 értéke / Actual Value of digital input 9

55

DI10 állapota / DI10 Status

R

Dig.bemenet 10 értéke / Actual Value of digital input 10

56

Riasztás AI7 érzékelő / Probe  alarm AI7

R

AI7 érz.hibás v. nem csatl./Probe broken or disconnected 

AI7

57

Riasztás AI8 érzékelő  / Probe  alarm AI8

R

AI8 érz.hibás v. nem csatl./Probe broken or disconnected 

AI8

58

Riasztás AI9 érzékelő  / Probe  alarm AI9

R

AI9 érz.hibás v. nem csatl./Probe broken or disconnected 

AI9

59

Riasztás AI10 érzékelő  / Probe  alarm AI10

R

AI10 érz.hibás v. nem csatl./Probe broken or disconnected 

AI10

60

Riasztás AI11 érzékelő / Probe  alarm AI11

R

AI11 érz.hibás v. nem csatl./Probe broken or disconnected 

AI11

SIG elektronikus vezérlés használati útmutató - 

SIG Controller User manual

21

12 - MODBUS

   

12 - MODBUS 

  

Summary of Contents for SIGB

Page 1: ...SZEREL SI HASZN LATI S KARBANTART SI TMUTAT INSTALLATION USE AND MAINTENANCE MANUAL SIGB SIGQ INTEGR LT VEZ RL RENDSZER EVO MANAGEMENT SYSTEM...

Page 2: ...SIG elektronikus vez rl s haszn lati tmutat SIG Controller User manual 2...

Page 3: ...0 8 zemm dok 12 9 Minim lis bef vott leveg h m rs klet 14 10 jszakia fordulatsz m cs kkent s 15 11 Men lista 15 12 Modbus 17 13 Riaszt sok 22 14 Az rz kel k helyzete 23 15 T vvez rl s 23 pag 1 General...

Page 4: ...Megjegyz s a vez rl st s a t vm k dtet t sszek t 6 eres telefon k bel nem r sze a sz ll t snak Err l a kivitelez nek kell gondoskodnia RJ12 csatlakoz val 1 General features SIG system makes the manag...

Page 5: ...Analog input 910 GND ID1 GND Digit lis bemenet Digital input T voli On Off Remote On Off 911 GND ID2 GND Digit lis bemenet Digital input Fagyv delem Antifreeze 912 GND ID3 GND Digit lis bemenet Digit...

Page 6: ...st ban a be rt rt k n vel se Enter gomb bel p s az almen be a be rt rt k j v hagy sa Down gomb l ptet s a param ter list ban a be rt rt k cs kkent se A kijelz n megjelen szimb lumok magyar zata 1 1 Az...

Page 7: ...an move on it pushing the arrow down button from the main screen and changing fans speed item only one item for all fans In the second case fan speed is automatically calculated from the value read fr...

Page 8: ...e read from probe default connected on B6 and by the set point that can be modified in fans speed screen Analog input It is used with EC fans modulating fans Here the fans speed changes following anal...

Page 9: ...of supply air temperature probe the probe must be placed after all thermal treatments in that circuit with exception of minimal supply function please see the specific chapter for it We suggest to se...

Page 10: ...ommand If the NO value is selected the local com mand prevails on all other commands and the final result will be the unit on off according to local command If YES value is selected the local command...

Page 11: ...he blinking cursor up to No value in the required row as for example from digital input but in the same way for time band and change it in YES value 8 Come back to the main screen pushing several time...

Page 12: ...the unit will be at 19 00 9 It is possible to copy the setting of the current day in the other days using the copy to function SET1 and SET2 values are now editable in the B02 screen they are dif fere...

Page 13: ...If speed reduction is selected item reduction fan speed is shown and it is the of speed reduction of supply fan compared to exhaust air fan speed which is working before starting of defrost action In...

Page 14: ...ut n van be p tve a rendszerbe Ebben az esetben ha a h cser l nem elegend a k v nt minim lis bef vott leveg h m rs klet biztos t s ra an lk l hogy egy lland elektromos f t s lenne az elsz vott leveg g...

Page 15: ...d settings D Info In Out D Input Output D01 A digit lis kimenetek llapota Digital output state D Info In Out D Input Output D02 Az anal g kimenetek rt ke Analog output value D Info In Out D Input Outp...

Page 16: ...t used H Gy rt i H Manufacturer a be ll t s a configuration Ha01 A berendez s t pus nak a be ll t sa default unit type configuration H Gy rt i H Manufacturer a be ll t s a configuration Ha02 rz kel a...

Page 17: ...g h m rs klet rz kel Supply Probe temperature C R Besz vott leveg h m rs klet rz kel ltal m rt h m rs klet Temperature measured by supply air probe 4 Kibocs tott leveg h m rs klet rz kel Exhaust Probe...

Page 18: ...ooling csak h t s 3 Only fan csak keringtet s 211 zemm d Running mode 0 R W 0 Heat Recovery h visszanyer 1 AHU l gkezel 212 J gtelen t s m d Defrost mode 0 R W 0 not active 1 electric 2 speed reductio...

Page 19: ...d percben Delay fan start for damper opening in second 229 Ut nkezel s zemm d 1 Post treatment 1 running mode 0 R W 0 Auto 1 Man Off 2 Man On 230 Ut nkezel s zemm d 2 Post treatment 2 running mode 0 R...

Page 20: ...v nem csatl Probe broken or disconnected AI1 21 Riaszt s az AI2 rz kel t l Probe alarm AI2 R AI1 rz hib s v nem csatl Probe broken or disconnected AI2 22 Riaszt s az AI3 rz kel t l Probe alarm AI3 R A...

Page 21: ...f digital input 7 53 DI8 llapota DI8 Status R Dig bemenet 8 rt ke Actual Value of digital input 8 54 DI9 llapota DI9 Status R Dig bemenet 9 rt ke Actual Value of digital input 9 55 DI10 llapota DI10 S...

Page 22: ...gy nem csatlakozik Probe B11 fault or disconnected Al13 B12 rz kel hib s vagy nem csatlakozik Probe B12 fault or disconnected Al14 Riaszt s ventil tor h v delem thermal fan protection alarm A ventil t...

Page 23: ...kat az eszk zzel egy tt sz ll tj k Az al bbi k pen l that a TUP bek t si v zlata A sz ks ges kieg sz t csatlakoz t be p tik a berendez sbe Ha a megrendel skor k rik akkor be p tenek m g egy csatlakoz...

Page 24: ...NOTES SIC reserves the right to modify data pictures and all that is related to this printed matter without any notice FORGALMAZ SOLARONICS CENTRAL EUROPE KFT 1238 Budapest Grassalkovich t 40 tel 36...

Reviews: