14
Operation of the LCD display
The LCD display is operated via the navigation keys (see
). On the right edge
of the LCD display, there are also arrows showing in which direction further menu items
can be accessed via the navigation keys.
Once you have selected the desired menu line using the navigation keys, press the “Enter”
key to execute the menu item.
If no entry is made for longer than 30 seconds, the first menu item “Status of the
MaxWeb XPN” automatically appears again.
If the menu is not operated for one minute, the display is dimmed and is in inactive state.
Standby mode
Note
To use the full scope of functions of the MaxWeb XPN, the device must be
continuously switched on. If the device is in standby mode, the functions can
no longer be used via the web browser.
Execute the following steps to switch the MaxWeb XPN to standby mode:
1. Select the “MaxWeb info” menu in the LCD display using the navigation keys and then
press the “Enter” key.
2. Now select the “Switch off XPN” menu using the navigation keys and then press the
“Enter” key (~5 seconds).
3. The MaxWeb XPN is now in standby mode and is no longer accessible via any
interface.
To restart the MaxWeb XPN, press the “ESC” key for at least 5 seconds. After about
30 seconds, the MaxWeb XPN is again fully operational.