background image

17

www

.

solarland

.

com

.

au

6. Maintenance

To ensure optimum module performance, SOLARLAND recommends the following maintenance measures:

Clean the glass surface of the module when required. Always use clean water and a soft sponge or cloth for 
cleaning. A mild, non-abrasive cleaning agent may be used to remove stubborn dirt.
Check the electrical, grounding and mechanical connections every six months to verify that they are clean, 
secure, undamaged and free of corrosion.
If any problem arises, consult a professional for suggestions.
Caution: observe the maintenance instructions for all components used in the system, such as support frames, 
charging regulators, inverters, batteries etc.

7. Shutting down the system

Completely cover system modules with an opaque material to prevent electricity from being generated while 
disconnecting conductors.
Disconnect system from all power sources in accordance with instructions for all other components used in the 
system.
The system should now be out of operation and can be dismantled. In doing so, observe all the safety 
instructions as applicable to installation.

8. Disclaimer of liability

Because the use of this manual and the conditions or methods of installation, operation, use and maintenance of 
photovoltaic products are beyond SOLARLAND’s control; SOLARLAND does not accept responsibility and 
expressly disclaims liability for loss, damage, or expense arising out of or in any way connected with such 
installation, operation, use or maintenance. No responsibility is assumed by SOLARLAND for any infringement of 
patents or other rights of third parties, which may result from use of the PV product. No license is granted by 
implication or otherwise under any patent or patent rights. The information in this manual is based on 
SOLARLAND’s knowledge and experience and is believed to be reliable, but such information including product 
specification (without limitations) and suggestions does not constitute a warranty, expressed or implied. 
SOLARLAND reserves the right to change the manual, the product, the specifications, or product information 
sheets without prior notice.

Please consult your distributor or the manufacturer concerning the warranty of your modules. If you have any 
further questions, your dealer will gladly assist you. Subject to technical modifications without notice.

Presented by:
Solarland Australia Pty. Ltd.

Add:

Tel: 
Fax: 
Email: 
Website: 

14/235 Spit Rd 
Mosman
NSW      2088 
Australia
1300 228 996
(02) 9969 3770
[email protected]
www.solarland.com.au

Manufactured by:
Wuxi Tianran Photovoltaic Co., Ltd.

Add:

Tel:
Fax:
Email:
Website:

B11 Huayou Dong Rd., Huayou Ind. Area,
National High-tech Industrial Area, 214028
WUXI, Jiangsu, China

+86-510-81191956
+86-510-85203812
[email protected]
www.solarland.com

Summary of Contents for SLP010-12V

Page 1: ...INSTALLATION INSTRUCTION FOR SLPXXX 12V SERIES SOLAR MODULE INSTALLATION INSTRUCTION FOR SLPXXX 12V SERIES SOLAR MODULE...

Page 2: ...formance Parameters 2 Mechanical Parameters 3 Purpose of this guide 4 General 5 Mechanical Installation 6 Maintenance 7 Shutting down the system 8 Disclaimer of liability Page 01 Page 01 Page 13 Page...

Page 3: ...17 0V 0 58A 21 6V 0 68A 3 1000V 1 A SLP015 12V 15W 17 2V 0 87A 21 6V 0 96A 3 1000V 2 A SLP020 12V 20W 17 2V 1 16A 21 6V 1 31A 3 1000V 2 A SLP025 12V 25W 17 2V 1 45A 21 6V 1 60A 3 1000V 2 A SLP030 12V...

Page 4: ...7A 22 0 V 5 07 A 3 1000V 7 A SLP120 12V 120 W 17 2 V 6 98A 21 2 V 7 62 A 3 1000V 15 A Value Parameters Max Power Pmax Operating Voltage Vmp Operating Current Imp Open Circuit Voltage Voc Short Circuit...

Page 5: ...4 9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zone Hengda Ele...

Page 6: ...ycrystalline silicon cells 4 9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical...

Page 7: ...icon cells 2x18 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zon...

Page 8: ...ycrystalline silicon cells 4 9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical...

Page 9: ...1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd 1...

Page 10: ...stalline silicon cells 4x9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Deve...

Page 11: ...n cells 4x9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zone He...

Page 12: ...ine silicon cells 4x9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB001 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Developme...

Page 13: ...s 4x9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB001 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zone Hengda E...

Page 14: ...n cells 4x9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB003A Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zone H...

Page 15: ...ponents Doing so will void the warranty Do not apply paint or adhesive to the module Do not use mirrors or other hardware to artificially concentrate sunlight on the module When installing modules obs...

Page 16: ...frame Each module or series string of modules so connected shall be provided with the maximum series fuse as specified C Mounting methods The module mounting structure must be made of durable corrosi...

Page 17: ...s in the frame on the long side of the panel and not the short side as shown below 200 200 When mounting the panel with the provided mounting holes mounting must comply with the minimum requirements s...

Page 18: ...ection of the cables and the capacity of the connectors must be selected to suit the maximum system short circuit current The recommended cable is PV wire with a cross section of at least 4mm2 and the...

Page 19: ...OLARLAND s control SOLARLAND does not accept responsibility and expressly disclaims liability for loss damage or expense arising out of or in any way connected with such installation operation use or...

Page 20: ......

Reviews: