background image

13

www

.

solarland

.

com

.

au

3. Purpose of this guide

Please carefully read the following installation and safety instructions. Non-compliance 
with these instructions may void the module warranty. 

This guide contains information regarding the installation and safe handling of SOLARLAND photovoltaic 
modules (hereafter referred to as "modules"). All instructions should be read and understood before attempting 
installation. If there are any questions, please contact your dealer or SOLARLAND for further information.
The installer should conform to all safety precautions in the guide when installing modules. Before installing a 
solar photovoltaic system, the installer should become familiar with the mechanical and electrical requirements 
for photovoltaic systems. Keep this guide in a safe place for future reference.

4. General

Installing solar photovoltaic systems requires specialized skills and knowledge. The installer assumes all risk 
of injury, including risk of electric shock. Module installation should be performed only by qualified persons.
All modules come with a permanently attached junction box and #12 AWG (4 mm2) wire terminated in PV 
connectors. Your dealer can provide additional extension cables to simplify module wiring.
Exercise caution when wiring or handling modules exposed to sunlight.
Do not disconnect wires connected to a photovoltaic module when it is exposed to sunlight, an electric arc may 
occur. Arcs can cause burns, start fires or otherwise create safety problems. Exercise caution when 
disconnecting wiring on modules.
Photovoltaic solar modules convert light energy to direct-current electrical
energy, and are designed for outdoor use. Proper design of support structures is the responsibility of the 
system designer and installer.
Modules may be ground mounted, pole mounted, or mounted on rooftops.

Do not attempt to disassemble the module, and do not remove any attached nameplates or 
components. Doing so will void the warranty.

Do not apply paint or adhesive to the module.

Do not use mirrors or other hardware to artificially concentrate sunlight on the module.

When installing modules observe all applicable local, regional and national codes & regulations. Obtain a 
building and/or electrical permit where required.

A. Safety precautions for installing a solar photovoltaic system

Solar modules produce electrical energy when exposed to sunlight.
Only connect modules with the same rated output current in series. If modules are connected in series, the 
total voltage is equal to the sum of the individual module voltages.
Only connect modules or series combinations of modules with the same voltage in parallel. If modules are 
connected in parallel, the total current is equal to the sum of individual module or series combination currents.
Keep children well away from the system while transporting and installing mechanical and electrical 
components.
Completely cover all modules with an opaque material during installation to prevent electricity from being 
generated.

Do not wear metallic rings, watchbands, ear, nose, or lip rings or other metallic devices while installing 
or troubleshooting photovoltaic systems.
Use appropriate safety equipment (insulated tools, insulating gloves, etc.) approved for use on 
electrical installations.

Observe the instructions and safety precautions for all other components used in the system, including wiring 
and cables, connectors, DC-breakers, mounting hardware, inverters, etc.
Use only equipment, connectors, wiring and mounting hardware suitable for use in a photovoltaic system.
Always use the same type of module within a particular photovoltaic system.
Under normal operating conditions, PV modules will produce currents and voltages that are different than 
those listed in the data sheet. Data sheet values are applicable at standard test data.
Short-circuit current and open-circuit voltages should be multiplied by a factor of 1.25 when determining 
component voltage ratings, conductor ampacity, fuse sizes and size of controls connected to the module or 
system output. 

Summary of Contents for SLP010-12V

Page 1: ...INSTALLATION INSTRUCTION FOR SLPXXX 12V SERIES SOLAR MODULE INSTALLATION INSTRUCTION FOR SLPXXX 12V SERIES SOLAR MODULE...

Page 2: ...formance Parameters 2 Mechanical Parameters 3 Purpose of this guide 4 General 5 Mechanical Installation 6 Maintenance 7 Shutting down the system 8 Disclaimer of liability Page 01 Page 01 Page 13 Page...

Page 3: ...17 0V 0 58A 21 6V 0 68A 3 1000V 1 A SLP015 12V 15W 17 2V 0 87A 21 6V 0 96A 3 1000V 2 A SLP020 12V 20W 17 2V 1 16A 21 6V 1 31A 3 1000V 2 A SLP025 12V 25W 17 2V 1 45A 21 6V 1 60A 3 1000V 2 A SLP030 12V...

Page 4: ...7A 22 0 V 5 07 A 3 1000V 7 A SLP120 12V 120 W 17 2 V 6 98A 21 2 V 7 62 A 3 1000V 15 A Value Parameters Max Power Pmax Operating Voltage Vmp Operating Current Imp Open Circuit Voltage Voc Short Circuit...

Page 5: ...4 9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zone Hengda Ele...

Page 6: ...ycrystalline silicon cells 4 9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical...

Page 7: ...icon cells 2x18 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zon...

Page 8: ...ycrystalline silicon cells 4 9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical...

Page 9: ...1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd 1...

Page 10: ...stalline silicon cells 4x9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Deve...

Page 11: ...n cells 4x9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB030 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zone He...

Page 12: ...ine silicon cells 4x9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB001 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Developme...

Page 13: ...s 4x9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB001 Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zone Hengda E...

Page 14: ...n cells 4x9 in series PV1 F 1 4 0mm2 Wuxi Xinhongye Wire Cable Co Ltd PV JB003A Ningbo Economic Technical Development Zone Hengda Electrical Co Ltd PV ST01 Ningbo Economic Technical Development Zone H...

Page 15: ...ponents Doing so will void the warranty Do not apply paint or adhesive to the module Do not use mirrors or other hardware to artificially concentrate sunlight on the module When installing modules obs...

Page 16: ...frame Each module or series string of modules so connected shall be provided with the maximum series fuse as specified C Mounting methods The module mounting structure must be made of durable corrosi...

Page 17: ...s in the frame on the long side of the panel and not the short side as shown below 200 200 When mounting the panel with the provided mounting holes mounting must comply with the minimum requirements s...

Page 18: ...ection of the cables and the capacity of the connectors must be selected to suit the maximum system short circuit current The recommended cable is PV wire with a cross section of at least 4mm2 and the...

Page 19: ...OLARLAND s control SOLARLAND does not accept responsibility and expressly disclaims liability for loss damage or expense arising out of or in any way connected with such installation operation use or...

Page 20: ......

Reviews: