7/19/1999
8
1 LOW WATER ELECTRODE
5 SOLAR MODULES NEG.
2 HIGH WATER ELECTRODE
6 PUMP NEGATIVE
3 GROUND ELECTRODE AND
7 PUMP POSITIVE
REMOTE SWITCH GROUND
4 REMOTE SWITCH POSITIVE
8 SOLAR MODULES POS.
SOLAR MODULE PRESET VOLTAGE SETTINGS
1 ON FOR 2 MODULES WIRED IN SERIES (30 VOLTS)
2 ON FOR 3 MODULES WIRED IN SERIES (45 VOLTS)
3 ON FOR 4 MODULES WIRED IN SERIES (60 VOLTS)
4 FOR FACTORY USE ONLY
REMOTE SWITCH SETTINGS
5 ON FOR REMOTE SWITCH CUT-OFF ON OPEN CONTACTS
OFF FOR REMOTE SWITCH CUT-OFF ON CLOSED CONTACTS
6 ON FOR ELECTRODE LOW WATER CUT-OFF
OFF FOR ELECTRODE HIGH WATER CUT-OFF
Summary of Contents for PCA 8-60B
Page 1: ...PCA 8 60B SDS SUBMERISIBLE PUMP CONTROLLER USER S MANUAL...
Page 7: ...7 19 1999 7...
Page 9: ...7 19 1999 9 WELL ELECTRODE INSTALLATION...
Page 10: ...7 19 1999 10...
Page 11: ...7 19 1999 11...
Page 12: ...7 19 1999 12...