7/19/1999 

CONTROLLER ADJUSTING PROCEEDURE 

 

 

The PC series controller has an easy to adjust pre-set voltage selector switch. 
This six position selector DIP switch is located on the face of the controller 
and has three preset voltage settings for various panel and battery 
arrangements. Please refer to the chart below for the switch position for your 
system.  
 
Only one of the first 3 switches should be in the on position at one time. These 
preset voltage settings will work with most standard solar modules on the 
market. If you need to change these voltage set points the "panel voltage 
adjusting pot" will allow you to do so. (Refer to the controller adjusting 
procedures below). CAUTION: Improper adjustment of this pot will decrease the 
flow rate of the pump or will not allow the controller to turn on.
 
 
The controller is designed to hold the voltage constant around the maximum power 
point of the panels. The set points available on this controller are as follows:  

 

Switch No.       Used For           Voltage Set Point 

 

1. 30 Volt Panel Direct  

26.0  

2. 45 Volt Panel Direct  

41.O  

3. 60 Volt Panel Direct  

54.0  

4. For Factory Use Only  
5. Remote Switch Logic  
6. Electrode Logic  
 
The purpose of this procedure is to adjust the voltage of the PV array to its 
peak power point and thus obtain the maximum water delivery from the pump. This 
procedure should be performed with the panels at their normal operating 
temperature at mid-day and the appropriate DIP switch in the up position.  
 
1. With the system installed and pumping water, turn the panels away from the 
sun until the pump flow rate is reduced by approximately 50%. If this is not 
possible then shade the panels slightly until you obtain the same results.  
 
2. Connect a DC volt meter to the pump side of the controller. 

(LD+ and LD-)  

 
3. Turn the small brass adjusting screw on the "Panel Voltage Adjusting Pot", 
located on the front of the controller, in both directions until the highest 
possible voltage is obtained.  
 
4. Return the panels to their normal position. The pump will then operate at its 
maximum output.  
 

Summary of Contents for PCA 8-60B

Page 1: ...PCA 8 60B SDS SUBMERISIBLE PUMP CONTROLLER USER S MANUAL...

Page 2: ...you how to make the connections for your particular system configuration Additional options are also explained and the wiring diagrams are given PCA 8 60B SPECIFICATIONS Input Voltage 24 80V Open Circ...

Page 3: ...DIP SWITCH 6 ON Low water cut off 1 LO LOW WATER LEVEL SENSOR turns the pump off Mount an E 1s electrode 2 above the ground sensor 2 HI HIGH WATER LEVEL SENSOR turns the pump on Mount an E 1s brass el...

Page 4: ...oints available on this controller are as follows Switch No Used For Voltage Set Point 1 30 Volt Panel Direct 26 0 2 45 Volt Panel Direct 41 O 3 60 Volt Panel Direct 54 0 4 For Factory Use Only 5 Remo...

Page 5: ...cross terminals 5 PV and 6 LD this will bypass the controller and will allow the pump to run panel direct Note You must have full or almost full sun for this test to be valid 3 Make sure the proper vo...

Page 6: ...controller will not turn on See controller adjustment section 4 Check to see if the float switch if used is functioning properly Disconnect wires from terminals 3 4 to bypass float circuit 5 Make sure...

Page 7: ...7 19 1999 7...

Page 8: ...S POS SOLAR MODULE PRESET VOLTAGE SETTINGS 1 ON FOR 2 MODULES WIRED IN SERIES 30 VOLTS 2 ON FOR 3 MODULES WIRED IN SERIES 45 VOLTS 3 ON FOR 4 MODULES WIRED IN SERIES 60 VOLTS 4 FOR FACTORY USE ONLY RE...

Page 9: ...7 19 1999 9 WELL ELECTRODE INSTALLATION...

Page 10: ...7 19 1999 10...

Page 11: ...7 19 1999 11...

Page 12: ...7 19 1999 12...

Page 13: ...r of the product voids all warranty Warranty limitations There are no express warranties except as listed above SOLARJACK shall have no responsibility for damage to property persons animals or other l...

Reviews: