INSTALLATION

The fixture is designed for indoor use only and must be used in a dry location with adequate 

ventilation. Ensure that none of the fixture’s ventilation slots are blocked and ensure that the 

fixture is fastened to a secure structure or surface. Do not use the fixture to illuminate sur

-

faces less than 8 m (approx 26ft.) from the fixture.

FASTENING THE FIXTURE TO A FLAT SURFACE

The fixture can be fastened to a hard, fixed, flat surface that is oriented at any angle. Ensure 

that the surface and all fasteners used can support at least 10 times the weight of all fixtures 

and equipment they will support. Fasten the fixture Securely. Do not place it on a surface or 

leave it where it can be moved or fall over. If you install the fixture in a location where it may 

cause injury or damage if it falls, secure it as directed below with a securely anchored safety 

cable that will hold the fixture if the primary fastening method fails.

MOUNTING THE FIXTURE ON A TRUSS

The fixture can be clamped to a truss or similar rigging structure in any orientation. When 

installing the fixture hanging vertically down, you can use an open-type clamp such as a 

G-clamp. When installing in any other orientation, you must use a half-coupler clamp

that completely encircles the truss or pipe circumference. To clamp the fixture to a truss:

1. Check that the rigging structure can support at least 10 times the weight of all fixtures and 

equipment  to be installed on it.

2. Block access under the work area.

3. Working from a stable platform, hang the fixture on the

 truss and  fasten the rigging clamps onto the truss.

4. Secure the fixture with a safety cable as directed below.

5. Check that the head will not collide with other fixtures or objects.

SECURING WITH A SAFETY CABLE

Secure the fixture with a safety cable (or other secondary attachment) that is approved for 

the weight of the fixture so that the safety cable will hold the fixture if a primary attachment 

fails. Loop the safety cable through and around a secure metal anchoring point.

WARNING! READ SAFETY INFORMATION ON    

PAGE 3 BEFORE INSTALLING THE FIXTURE.

Summary of Contents for PIX 72

Page 1: ...USER MANUAL PIX 72 basic pixel bar 24x3w...

Page 2: ...5 INSTALLATION 6 AC POWER 7 FIXTURE OVERVIEW 8 DMX DATA LINK 9 CONNECTING AND USING DMX DATA LINK 9 FIXTURE OPERATION 10 TOKENS 11 FIXTURE MENU STRUCTURE CHART 12 DMX MODES CHARTS 13 14 MAINTENANCE 1...

Page 3: ...RSONAL SAFETY Avoid direct eye exposure to the light source while the product is on Always disconnect this product from its power source before servicing Always connect this product to a grounded circ...

Page 4: ...nses LED lights or cables Have the damaged parts replaced by an authorized technician at once Do not cover the ventilation slots when operating to avoid internal overheating Do not aim this product to...

Page 5: ...SING THE PRODUCT FOR THE FIRST TIME 1 Read Safety information on page 4 before installing operating or servicing the fixture 2 Unpack and ensure that there is no transportation damage before using the...

Page 6: ...MOUNTING THE FIXTURE ON A TRUSS The fixture can be clamped to a truss or similar rigging structure in any orientation When installing the fixture hanging vertically down you can use an open type clamp...

Page 7: ...l installation if you want to install it permanently or a power plug not supplied that is suitable for the local power out lets can be installed on the power cable If you replace power plug on the pow...

Page 8: ...Screen for accessing menu with 4 buttons for navigation Up Down Inc In crement and Dec Decrement Enter UP Press UP to toggle between menu options DOWN Press DOWN to toggle between menu options INC Pr...

Page 9: ...l of a fixture is required it must have its own DMX channels Fixtures that are required to behave identically can share the same DMX address and channels To add more fixtures or groups of fixtures whe...

Page 10: ...g the up down buttons below the screen you can control the desired dimmer level You can also manually control strobe flashing by changing the values when the back screen shows FF00 strobe flash By set...

Page 11: ...ng Solaris fixtures The TOKENS are located above the digital screen on the back panel of the fixture This token indicates the maximum amount of power consumption Displays in Watts This token indicates...

Page 12: ...ect2 speed slow to fast 14 3J00 00 20 Program Effect3 speed slow to fast 15 4J00 00 20 Program Effect4 speed slow to fast 16 5J00 00 20 Program Effect5 speed slow to fast 17 6J00 00 20 Program Effect6...

Page 13: ...peed from slow to fast 4 CHANNELS MODE NO DMX VALUE FUNCTION 1 000 255 Master LED Dimmer 1 100 2 000 255 RED LED Dimmer 1 100 3 000 255 GREEN LED Dimmer 1 100 4 000 255 BLUE LED Dimmer 1 100 12 CHANNE...

Page 14: ...ection 7 Red Dimmer 1 100 20 000 255 Section 7 Green Dimmer 1 100 21 000 255 Section 7 Blue Dimmer 1 100 22 000 255 Section 8 Red Dimmer 1 100 23 000 255 Section 8 Green Dimmer 1 100 24 000 255 Sectio...

Page 15: ...tdoor events for example If one or more of these factors is present inspect fixtures within their first 100 hours of operation to see whether cleaning is necessary Check again at frequent intervals Th...

Page 16: ...DIMENSIONS Length 1010 mm 40 4 Width 60 mm 2 4 Height 65 mm 2 6 LAMP Lamp type 24 X 3W 3 in 1 Color system RGB Temperature Adjustable FEATURES Pre Programed Effects 13 Dynamic effects with adjustable...

Page 17: ...witch Mode INCLUDED ITEMS 3 ft Power Cable User Manual Specifications are subject to change without notice For latest product specifications see www Glow Lighting com CONTROL AND PROGRAMMING Control S...

Page 18: ...LOSS OCCASIONED BY THE USE OF INABILITY TO USE OR RELIANCE ON THE INFORMATION CONTAINED IN THIS MANUAL THE GLOW LOGO THE SOLARIS LOGO THE GLOW PROFESSIONAL NAME THE SOLARIS PROFESSIONAL NAME AND ALL O...

Reviews: