background image

MMA-211 

 

 

Notice 

Welding  power  source  unless  you  have  special  needs,  maintenance  must  be  cut  off  power 
distribution box, ensure that under the premise of safety. If you don't abide by the above principles, 
could lead to electric shock, burns and other major accident about personal safety. 

Don't put welding machine long time exposure in the sun. 

Welder used when had better not put in strong sunlight. 

Don't put welding machine in rain. 

Don't put welding machine in wet place long time. 

when use welding machine to ensure the vent is not covered. 

The welder should use, store in a well-ventilated environment. 

Shall to open the chassis, with dry compressed air cleaning machine or a vacuum cleaner to clean 
up the internal dust and metal scrap at least per six months. 

Check all welding cable insulation skin to see if there is any breakage,or replace the cable. 

Regularly  check  all  electrical  connection  parts  in  the  welding  machine  if  there's  any  loose  parts, 
and tighten loose parts. 

Please take good care of all equipment, don't make them by man-made damage. 

 

TECHNICAL DATA SYMBOLS 

 

The user is not allowed to dispose ofthese 
appliances as solid, mixed urban refuse, 
and must do it through authorised refuse 
collection centres 

U

0

 

Maximum no-load voltage, V 

 

General hazard. Please, read manual 
before using 

U

1

 

Power supply voltage, V  

 

welding operations may be carried out in 
environments with heightened risk of 
electric shock 

Duty cycle, % 

 

The electric arc produces 
dangerous rays for eyes and 
skin. Protect yourself! 

I

Welding output current, A 

 

Danger of fumes, fire and burns 

U

2

 

The welding voltage corresponding 
to the output current, V 

 

Symbol of power supply line 

IP21S 

Protection rating of the covering 

 

ММА – Manual Metal Arc 

I

1max

 

Maximum absorbed current, A 

 

DC current welding 

I

1eff

 

Effective current supplied, A 

 

Symbol for internal structure of welding machine 

 

 

 

 

 

 

Summary of Contents for MMA-211

Page 1: ...ual De Instruc iuni SALDATRICI INVERTER INVERTER WELDER SOLDADOR INVERTER INVERTER SCHWEI GER T SV E KY INVERTOR HEGESZT INVERTER INVERTER METIN T JS SUVIRINIMO APARATAS INVERTOR SUDOR MMA 211 Attenti...

Page 2: ...2 MMA 211 160 50201...

Page 3: ...hould be carried out after the distri bution box to disconnect the power switch Welding machine should be placed as far as possible the tilt Angle should not be greater than 10 degrees WARNING Electri...

Page 4: ...n the left 4 grounding and welding cable should be short 5 do not in the vicinity of welding power source construction In order to prevent the eyes and skin injury please obey the rules of the labor s...

Page 5: ...orkpiece anti stick protection against welding electrodes during welding SAFETY FEATURES Protection from abnormal conditions Under the load bearing elements heat up considerably Therefore in the devic...

Page 6: ...d breaker or fuse Model Input voltage Max input current Rated input current Cross section of ground cable Fuse MMA 211 230 V 24 4 A 13 3 A 2 5 mm 2 25 A Connection Connecting the welding cable connect...

Page 7: ...turned on after welding for cooling fan from 3 to 5 minutes If the yellow LED lights up this means thermal protection Please keep power on for cooling inner components Turn off the welding machine aft...

Page 8: ...breakage or replace the cable Regularly check all electrical connection parts in the welding machine if there s any loose parts and tighten loose parts Please take good care of all equipment don t ma...

Page 9: ...MMA 211 9 SOLARIS IGBT 230...

Page 10: ...MMA 211 10 10...

Page 11: ...MMA 211 11 1 2 3 4 5 6 7 8 9 10 hot start arc force anti stick 2 1 5 4 3 6 9 7 8 10...

Page 12: ...MMA 211 12 MMA 211 230 50 60 1 70 210 A 28 4 20 210 A 40 EN 60974 1 30 20 60 13 3 A 24 4 3 8 5 5 1 6 4 0 0 92 COS 0 82 H IP21S 4 1 380...

Page 13: ...MMA 211 13 10 40 25 55 40 50 20 90 1 30 20 30 7 6 I1eff PE 230 50 MMA 211 230 24 4 A 13 3 A 2 5 mm 2 25 A 1 2...

Page 14: ...4 8 7 5 3 1 6 2 2 5 3 2 4 5 0 8 3 1 4 1 2 5 1 5 6 2 8 2 5 10 40 70 50 100 80 130 120 170 150 250 210 310 60 100 70 120 110 150 140 200 190 260 240 320 30 60 40 80 70 120 100 150 140 230 220 300 5 10 7...

Page 15: ...MMA 211 15 3 5 3 5 Solaris Solaris...

Page 16: ...MMA 211 16 U0 U1 X I2 U2 50 IP21S Manual Metal Arc I1max I1eff 25 55 90...

Page 17: ...MMA 211 17...

Page 18: ...6 Skipfire Limited Romanou 2 Tlais Tower 6th floor office 601 P C 1070 Nicosia Cyprus 18 4916 ECO Group 220103 50 302 375 17 290 90 90 105082 40 1 3 7 7 778 8540843 BY 112 11 01 004 003 29328 3 1 2 3...

Page 19: ...MMA 211 19 7 8 9 10 11...

Page 20: ...76 51 7 8 843 200 95 72 58 2 8 4842 57 58 46 2 8 48456 5 49 87 15 8 483 364 16 81 12 8 4712 51 20 10 1 12 8 495 783 02 02 8 8 483 364 16 81 98 8 4862 71 48 03 75 8 812 214 18 74 15 8 812 572 30 20 1...

Reviews: