background image

MMA-210 

 

 

 

Adjust welding current 

Turn the current adjustment potentiometer to set the desired welding current.  

 

 

Type of electrode 

Welding current

, А 

Diameter of electrode, mm

 

1,6 

2,5 

3,2 

Thickness of material, 

mm 

0,8-3 

1-4 

1,2-5 

1,5-6 

2-8 

2,5-10 

Rutile 

40-70 

50-100 

80-130 

120-170 

150-250 

210-310 

Basic 

60-100 

70-120 

110-150 

140-200 

190-260 

240-320 

Cellulosic 

30-60 

40-80 

70-120 

100-150 

140-230 

220-300 

 

Insert the welding electrode in the electrode holder 

Take the electrode and install it into the holder, touch the electrode to the material to the 
start  welding.  When  welding  keep  distance  5-10  mm  and  angle  around  70-

80°  from  the 

electrode to material. 

 

Replacing the electrodes 

When electrode burn to only 1 ~ 2 cm away from the electrode holder must be the new electrode, 
to carry out welding. 

Attention! Never turn off the machine immediately after work 

The machine should be turned on after welding for cooling fan from 3 to 5 minutes. 

 If  the  yellow  LED  lights  up,  this  means  thermal  protection.  Please  keep  power  on  for 
cooling inner components. 

 

Turn off the welding machine after using 

Press  off  the  power  switch  on  the  rear  panel  to  the  turn  off  the  welding  machine  after 
using. The power indicator will turn off after 3-5 seconds, and the fan stops. Remove the 
power plug from the power socket. 

 

REPAIR AND MAINTENANCE                                       

Inverter welding machine is that by the composition of many modern electronic components, high 
technology  contents,  is  a  high-tech  product,  so  the  technical  requirements  of  maintenance 
personnel  is  higher.  But  because  there  are  few  easy  wear  components,  so  every  day  except  the 
body  appearance  clean  job  need  to  be  maintained  on  a  regular  basis.  Repair  welding  shall  be 
conducted  by  professional  maintenance  personnel  are  responsible  for.  When  the  user  can't  rule 
out the failure or don't have the ability to repair, should be timely and contact the manufacturer or 
supplier, get technology, repairs, spare parts supply and service and support. 

 

Summary of Contents for MMA-210

Page 1: ...ual De Instruc iuni SALDATRICI INVERTER INVERTER WELDER SOLDADOR INVERTER INVERTER SCHWEI GER T SV E KY INVERTOR HEGESZT INVERTER INVERTER METIN T JS SUVIRINIMO APARATAS INVERTOR SUDOR MMA 210 Attenti...

Page 2: ...2 MMA 210 160 50201...

Page 3: ...hould be carried out after the distri bution box to disconnect the power switch Welding machine should be placed as far as possible the tilt Angle should not be greater than 10 degrees WARNING Electri...

Page 4: ...n the left 4 grounding and welding cable should be short 5 do not in the vicinity of welding power source construction In order to prevent the eyes and skin injury please obey the rules of the labor s...

Page 5: ...workpiece anti stick protection against welding electrodes during welding SAFETY FEATURES Protection from abnormal conditions Under the load bearing elements heat up considerably Therefore in the dev...

Page 6: ...d breaker or fuse Model Input voltage Max input current Rated input current Cross section of ground cable Fuse MMA 210 230 V 24 4 A 13 3 A 2 5 mm2 25 A Connection Connecting the welding cable connect...

Page 7: ...turned on after welding for cooling fan from 3 to 5 minutes If the yellow LED lights up this means thermal protection Please keep power on for cooling inner components Turn off the welding machine aft...

Page 8: ...breakage or replace the cable Regularly check all electrical connection parts in the welding machine if there s any loose parts and tighten loose parts Please take good care of all equipment don t ma...

Page 9: ...MMA 210 9 SOLARIS IGBT 230...

Page 10: ...MMA 210 10 10...

Page 11: ...MMA 210 11 1 2 3 4 5 6 7 8 9 10 hot start arc force anti stick 2 1 5 4 3 6 9 7 8 10...

Page 12: ...MMA 210 12 MMA 210 230 15 50 60 1 70 210 A 28 4 20 210 A 40 EN 60974 1 30 20 60 13 3 A 24 4 3 8 5 5 1 6 4 0 0 92 COS 0 82 H IP21S 4 1 380...

Page 13: ...MMA 210 13 10 40 25 55 40 50 20 90 1 30 20 30 7 6 230 50 MMA 210 230 24 4 A 13 3 A 2 5 mm2 25 A 1 2...

Page 14: ...8 7 5 3 1 6 2 2 5 3 2 4 5 0 8 3 1 4 1 2 5 1 5 6 2 8 2 5 10 40 70 50 100 80 130 120 170 150 250 210 310 60 100 70 120 110 150 140 200 190 260 240 320 30 60 40 80 70 120 100 150 140 230 220 300 5 10 70...

Page 15: ...MMA 210 15 3 5 Solaris Solaris...

Page 16: ...MMA 210 16 U0 U1 X I2 U2 50 IP21S Manual Metal Arc I1max I1eff 25 55 90...

Page 17: ...Skipfire Limited Romanou 2 Tlais Tower 6th floor office 601 P C 1070 Nicosia Cyprus 18 4916 ECO Group 220103 50 302 375 17 290 90 90 107076 14 XIII 41 7 778 8540843 BY 112 11 01 004 003 29328 3 1 2 3...

Page 18: ...MMA 210 18 7 8 9 10 11...

Page 19: ...76 51 7 8 843 200 95 72 58 2 8 4842 57 58 46 2 8 48456 5 49 87 15 8 483 364 16 81 12 8 4712 51 20 10 1 12 8 495 783 02 02 8 8 483 364 16 81 98 8 4862 71 48 03 75 8 812 214 18 74 15 8 812 572 30 20 1...

Page 20: ...MMA 210 20...

Reviews: