16 Maintenance and cleaning
15.4 Buffer tank loading
Fig. 2-53_01_124
This menu
1
is only visible when a buffer control in the
boiler control is enabled.
In the event of good weather being forecast, the buffer
tank is charged for a shorter time within the time
release.
The bar
2
can be used to set the level of influence for
each buffer tank individually.
0% = if the burner has started and the buffer tank is
within a time release, the buffer tank is completely
charged. The charge request is fulfilled when the
buffer
temperature, lower,
has reached the
maximum buffer
temperature, lower
(in the buffer tank main menu).
100 % = if the burner has started and the buffer tank is
within a time release, the buffer tank is not completely
charged. The charge request is already fulfilled when
the
buffer temperature, lower,
has exceeded the
mini-
mum buffer temperature, upper
(in the buffer tank main
menu).
16 Maintenance and cleaning
i
Regular maintenance and cleaning of the hea-
ting system are a prerequisite
n
for permanently reliable functioning of the
boiler,
n
for energy-saving and environmentally fri-
endly operation of the boiler,
n
for a long service life of the boiler.
Activities required
Depending on the type and scope of the maintenance,
a distinction is made as to who can perform it (system
operator SO or qualified personnel QP).
Activity
Interval
AB FP
Remove ash from the
combustion chamber
if there is a note rela-
ting to boiler clea-
ning
X
Cleaning the primary air
openings in the filling
chamber
regularly
X
Visual inspection of the
combustion grate
regularly
X
Visual check of the fire
clay bricks
half-yearly
X
Check system pressure
monthly
X
Clean exhaust gas duct
yearly
X
Check safety valve of the
boiler safety group
yearly
X
Maintenance by qualified
personnel
yearly
X
Perform emissions mea-
surement
as per regional regu-
lations
X
i
Always perform the cleaning activities detailed
above with the
boiler cleaning
function.
Ä
The operating hour counter for the clea-
ning internal is set to zero.
Ä
Heat exchanger cleaning is activated.
Remove ash from the combustion cham-
ber
►
Open the cladding door and combustion chamber
door.
►
Place the ash pans
1
in front of the combustion
chamber.
►
Clear the ash present in the combustion chamber
using the ash scraper in the ash pan.
Operation manual
therminator II touch
35