Installation
Installation manual
octo
plus
17
Fig. 5-6
Installing the corrugated hose
connectors
Mount 3 x piece corrugated hose
connector
1
with gasket
2
and
cap nut
3
.
Fig. 5-7
Mount tank temperature sensor
bottom
Insert 3 pcs temperature sensors
4
into the bracket and secure with
screw DIN7985-VZ/M4x10.
Lay cables for the sensors on the
top of the tank.
-
Top tank sensor, X30
-
Centre tank sensor, X31
-
Lower tank sensor, X32
Fig. 5-8
Dismantling retaining brackets
Loosen 4x hex nuts and washers
2
remove 2x retaining brackets
1
.