4.11 Technical specifications
maxi
mus
L
150
200
250
300
Wood chips output
[kW]
149
201
240
-
Pellets output
[kW]
149
201
250
299
Boiler class (acc. to EN 305:5 2012)
5
5
5
5
Dimensions
Width
[cm]
195
195
195
195
Height inc. adjustable feet
[1]
[cm]
214
214
214
214
Depth with ID fan
[cm]
222
222
222
222
Burner transport dimension - width
[cm]
90
90
90
90
Heat exchanger transport dimension -
width
[2]
[cm]
100
100
100
100
Heat exchanger transport dimension -
height
[cm]
210
210
210
210
Minimum room height
[3]
[cm]
275
275
275
275
Weight
Burner weight
[kg]
1321
1321
1321
1321
Heat exchanger weight
[kg]
1456
1456
1456
1456
Feeder unit weight
(inc. single axis rotary
valve)
[kg]
215
215
215
215
Total weight
(inc. ash container and feeder unit;
ready for operation, without fill-up water)
[kg]
3290
3290
3290
3290
Water side
Water content
(burner and heat exchanger)
[l]
565
565
565
565
Operating temperature
[°C]
70 - 90
70 - 90
70 - 90
70 - 90
Maximum permissible temperature
[°C]
90
90
90
90
Max. permissible operating pressure
[bar]
3
3
3
3
Min. return temperature
[°C]
60
60
60
60
Boiler flow/boiler return connection
[“]
G 2“ ET
G 2“ ET
G 2“ ET
G 2“ ET
Drain connection
[“]
G 1“ ET
G 1“ ET
G 1“ ET
G 1“ ET
Connection for thermal overload pro-
tection
[“]
G 1/2“ ET
G 1/2“ ET
G 1/2“ ET
G 1/2“ ET
Electrical connection
Connection, fuse
400 V AC, 50 Hz, 16 A, 3P+N+PE
Fuel
Fuel - wood chips
Wood chips in accordance with EN ISO 17225-4, classes A1,
A2, B1, sizes P16S and P31S; water content max. 35% (M35)
Fuel - wood pellets
Wood pellets according to EN ISO 17225-2
Flue gas side
Flue gas pipe diameter
[cm]
25
25
25
25
Height up to flue gas pipe upper edge
[1]
[cm]
214
214
214
214
Minimum draught requirement
[4]
[Pa]
5
5
5
5
Maximum flue gas temperature
[5]
full
load
[°C]
140
140
140
140
3 Warranty, guarantee, liability
12