Chapter 7: Setting Up Communication
Safety and Monitoring Interface Installation Manual – MAN-01-00067-2.1
45
45
Verifying the Connection
After each connection, perform the following to check that the connection to the monitoring server has
been established successfully.
►
To verify the connection:
1
Turn ON the AC to the SMI by turning on the circuit breakers on the main circuit board, and turn on
the SMI.
2
Wait for the SMI to connect to the SolarEdge monitoring server. This may take up to two minutes.
A message similar to the following appears on the LCD panel:
V d c [ v ] I d c [ a ] P d c [ w ]
1 4 . 1 - - . - - - - - - -
P _ O K : 0 1 4 / 0 1 4 < S _ O K >
O F F
S_OK
: Indicates that the connection to the SolarEdge monitoring server is successful.
If S_OK is not displayed, refer to Appendix A: Errors and Troubleshooting.