background image

SAFETY INSTRUCTIONS

1.  Use of an attachment not recommended or sold by manufacturer may result in a risk of fire, electric shock,  
  or injury to persons.

2.  To reduce risk of damage to electric plug and cord, pull by plug rather than cord when disconnecting unit.

3.  Make sure cord is located so that it will not be stepped on, tripped over, or otherwise subjected to damage  
  or stress.

4.  An extension cord should not be used unless absolutely necessary. Use of an improper extension cord could  
  result in a risk of fire and electric shock. If an extension cord must be used, make sure pins on plug of  
  extension cord are the same number, size, and shape as those of plug on unit; extension cord is properly  
  wired and in good condition; wire size is large enough for the length of cord as specified in the following  
 chart:
 

Length in feet: 

25  50 

100  150

 

Cord AWG size:  16  12   10     8

5.  Do not operate unit with damaged cord or plug - replace them immediately.

6.  Do not disassemble unit – take it to/or call a qualified technician when service or repair is required.   
  Incorrect reassembly may result in a risk of electric shock or fire.

7.  To reduce risk of electric shock, unplug unit from outlet before attempting any maintenance or cleaning.
 

PERSONAL SAFETY PRECAUTIONS

1.  Someone should be within range of your voice or close enough to come to your aid when you work near  
  a lead-acid battery. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing  
  or eyes.

2.  If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye,  
  immediately flood eye with running cold water for at least 10 minutes and get medical attention immediately.

3.  NEVER smoke or allow a spark or flame in vicinity of battery or engine.

4.  Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or short-circuit battery  
  or other electrical part that may cause explosion.

5.  Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a  
  lead-acid battery. A lead acid battery can produce a short circuit current high enough to weld a ring or  
  the like to metal, causing a severe burn.

6. When using unit as charger, charge LEAD-ACID batteries only. It is not intended to supply low-voltage 

 

  power for applications other than battery charging. Do not use with batteries that are commonly used  
  with home appliances. These batteries may burst and cause injury to persons and damage property.

7. NEVER JUMP START OR CHARGE a frozen battery. Any battery that is suspected of being frozen must 

 

  be thawed before jump starting or charging.

GROUNDING AND AC POWER CONNECTION INSTRUCTIONS

Unit should be grounded to reduce risk of electric shock. Unit is equipped with an AC electric cord having an 
equipment grounding conductor and a grounding plug. The plug must be plugged into an outlet that is properly 
installed and grounded in accordance with all local codes and ordinances.

Never alter the AC cord or plug provided – if it will not fit outlet, have proper outlet installed by a qualified 
electrician. This unit is for use on a 120 Volt, 60 Hz cycle circuit. A temporary adapter may be used to connect 
this plug to a two-pole receptacle if a properly grounded outlet is not available. The temporary adapter should 
be used only until a properly grounded outlet can be installed by a qualified electrician. Before using adapter, 
be certain that center screw of outlet plate is grounded. The green rigid ear or lug extending from adapter 
must be connected to a properly grounded outlet – make certain it is grounded. If necessary, replace original 
outlet cover plate screw with a longer screw that will secure adapter ear or lug to outlet cover plate and make 
ground connection to grounded outlet.

DANGER

Summary of Contents for HT1224AGM

Page 1: ...RATING UNIT WARNING WARNING 12 24 VOLT MODELS Never hook up a 12 Volt DC power source to a 24 Volt DC vehicle This will grossly overcharge the 12 Volt power source and generate flammable gasses that m...

Page 2: ...use Always follow the specific instructions in this manual and on the SOLAR Jump Starter each time you jump start using the SOLAR Jump Starter All lead acid batteries car truck and boat produce hydrog...

Page 3: ...risk of dropping a metal tool onto battery It might spark or short circuit battery or other electrical part that may cause explosion 5 Remove personal metal items such as rings bracelets necklaces and...

Page 4: ...receiving so you will have maximum power for your jumping needs 1 Unwrap AC power cord from unit and plug into 120VAC outlet 2 Charger will read internal battery status and apply the proper charge ne...

Page 5: ...Connect POSITIVE RED clamp from unit to POSITIVE POS P ungrounded post of battery Connect NEGATIVE BLACK clamp to vehicle chassis or engine block away from battery last Note Do not connect clamp to ca...

Page 6: ...tery by lifting battery up turning and sliding it out rear opening of unit INSTALLING NEW BATTERIES 1 Slide first battery in through rear opening turning battery so that its vent faces the front of un...

Page 7: ...batteries AGM for AGM batteries 13 Plug in Power Cord to charge the batteries The AMPS gauge will register the proper charge rate being applied to the batteries Internally both chargers will have a re...

Page 8: ...change outlet Check continuity of plug pins replace plug See figure of unit to check wiring connections Short across studs on gauge to see if charger comes on replace gauge Replace charger Possible C...

Page 9: ...caused by repairs made by an unauthorized person mishandling modifications normal wear unreasonable use or signs of battery acid corrosion from improper use or storage or damage to the SOLAR Commercia...

Page 10: ...ent sur le SOLAR chaque utilisation Toute batterie au plomb acide produit un gaz hydrog ne qui pourrait exploser avec violence en pr sence de flammes ou d tincelles Ne fumez pas n utilisez pas d allum...

Page 11: ...de de la batterie dans les yeux sur la peau ou sur les v tements 2 R agissez toujours rapidement en cas de contact avec de l acide Si de l acide est projet sur la peau ou les v tements lavez les imm d...

Page 12: ...le cordon lectrique C A ou la prise incluse ils ne sont pas compatible avec la prise de courant faites installer une sortie appropri e par un lectricien qualifi Cette unit sert sur un circuit de 120 v...

Page 13: ...urraient causer des dommages aux personnes 5 Brancher la pince rouge POSITIVE de l unit la borne POSITIVE position P sans prise de terre de la batterie Brancher pince noire N GATIVE au ch ssis du v hi...

Page 14: ...utilisation ult rieure NE touchez PAS aux bornes de la batterie car cela entra nerait un arc lectrique 7 Retirez la batterie sup rieure arri re en la soulevant vers le haut en la tournant et en la fa...

Page 15: ...rs m le double femelle simple sur le chargeur n 1 chargeur sup rieur 12 Assurez vous que le commutateur de ventilation de la batterie mont sur le double chargeur correspond au type de batterie install...

Page 16: ...eliez les goujons de la jauge pour voir si le chargeur fonctionne remplacez la jauge Remplacez le chargeur R glez la position 12 volts CAUSE POSSIBLE Les connexions rapides ne sont pas attach es ensem...

Page 17: ...E EN VERTU D UNE RUPTURE DE GARANTIE EXPRESSE OU TACITE D UNE N GLIGENCE D UNE RESPONSABILIT CIVILE D LICTUELLE AU SENS STRICT OU TOUTE AUTRE BASE JURIDIQUE Cette garantie s applique toute personne de...

Page 18: ......

Page 19: ......

Page 20: ...ual Model HT1224AGM Commercial Jump Starter This product can expose you to lead which is known to the State of California to cause birth defects or other reproductive harm and Vinyl Chloride Styrene a...