background image

Congratulations!

 You have just purchased the most versatile and dependable unit on the market today.  

Keep the unit plugged in when not in use

 

and it will provide long, continuous service and satisfaction.

The 

SOLAR

 Jump Starter is specifically designed to jump start 12 Volt and 24 Volt lead-acid  

batteries. Follow all battery/vehicle manufacturer’s jump starting or charging instructions. 

DO NOT JUMP START WITH AC POWER CORD CONNECTED TO 120 VOLT AC POWER SOURCE.

The unit’s charger will maintain its internal battery and will automatically shut off. When the AMPS gauge 

reaches zero, the onboard batteries are fully charged. The charger constantly monitors its storage battery. 

WARNING

Read these instructions completely before using the 

SOLAR

 Jump Starter and save them for future reference. 

Before using the 

SOLAR

 Jump Starter to jump start a car, truck, boat or to power any equipment, read these 

instructions and the instruction manualsafety information provided by the car, truck, boat or equipment 
manufacturer. Following all manufacturers’ instructions and safety procedures will reduce the risk of accident.

Working around lead-acid batteries may be dangerous. Lead-acid batteries release explosive gases during 
normal operation, charging and jump starting. Carefully read and follow these instructions for safe use. Always 
follow the specific instructions in this manual and on the 

SOLAR

 Jump Starter each time you jump start using 

the 

SOLAR

 Jump Starter.

All lead-acid batteries (car, truck and boat) produce hydrogen gas which may violently explode in the presence 
of fire or sparks. 

Do not smoke, use matches or a cigarette lighter while near batteries.

 Do not handle the 

battery while wearing vinyl clothing because static electricity sparks are generated when vinyl clothing is 
rubbed. Review all cautionary material on the 

SOLAR

 Jump Starter and in the engine compartment.

Always wear eye protection, appropriate protective clothing and other safety equipment when working near 
lead-acid batteries. Do not touch eyes while working on or around lead-acid batteries.

Always return clamps to their proper storage positions, away from each other or common conductors. Improper 
storage of clamps may cause the clamps to come in contact with each other, or a common conductor, causing 
the battery to short circuit and generate high enough heat to ignite most materials.

Use extreme care while working within the engine compartment, because moving parts may cause severe 
injury. Read and follow all safety instructions published in the vehicle's Owner's Manual.

While the battery in the 

SOLAR 

Jump Starter is a sealed unit with no free liquid acid, batteries being jump 

started with the 

SOLAR 

Jump Starter unit likely contain liquid acids which are hazardous if spilled.

DO NOT TIP UNIT OR LAY UNIT FLAT WITH BATTERY INSTALLED!

WARNING

Summary of Contents for HT1224AGM

Page 1: ...RATING UNIT WARNING WARNING 12 24 VOLT MODELS Never hook up a 12 Volt DC power source to a 24 Volt DC vehicle This will grossly overcharge the 12 Volt power source and generate flammable gasses that m...

Page 2: ...use Always follow the specific instructions in this manual and on the SOLAR Jump Starter each time you jump start using the SOLAR Jump Starter All lead acid batteries car truck and boat produce hydrog...

Page 3: ...risk of dropping a metal tool onto battery It might spark or short circuit battery or other electrical part that may cause explosion 5 Remove personal metal items such as rings bracelets necklaces and...

Page 4: ...receiving so you will have maximum power for your jumping needs 1 Unwrap AC power cord from unit and plug into 120VAC outlet 2 Charger will read internal battery status and apply the proper charge ne...

Page 5: ...Connect POSITIVE RED clamp from unit to POSITIVE POS P ungrounded post of battery Connect NEGATIVE BLACK clamp to vehicle chassis or engine block away from battery last Note Do not connect clamp to ca...

Page 6: ...tery by lifting battery up turning and sliding it out rear opening of unit INSTALLING NEW BATTERIES 1 Slide first battery in through rear opening turning battery so that its vent faces the front of un...

Page 7: ...batteries AGM for AGM batteries 13 Plug in Power Cord to charge the batteries The AMPS gauge will register the proper charge rate being applied to the batteries Internally both chargers will have a re...

Page 8: ...change outlet Check continuity of plug pins replace plug See figure of unit to check wiring connections Short across studs on gauge to see if charger comes on replace gauge Replace charger Possible C...

Page 9: ...caused by repairs made by an unauthorized person mishandling modifications normal wear unreasonable use or signs of battery acid corrosion from improper use or storage or damage to the SOLAR Commercia...

Page 10: ...ent sur le SOLAR chaque utilisation Toute batterie au plomb acide produit un gaz hydrog ne qui pourrait exploser avec violence en pr sence de flammes ou d tincelles Ne fumez pas n utilisez pas d allum...

Page 11: ...de de la batterie dans les yeux sur la peau ou sur les v tements 2 R agissez toujours rapidement en cas de contact avec de l acide Si de l acide est projet sur la peau ou les v tements lavez les imm d...

Page 12: ...le cordon lectrique C A ou la prise incluse ils ne sont pas compatible avec la prise de courant faites installer une sortie appropri e par un lectricien qualifi Cette unit sert sur un circuit de 120 v...

Page 13: ...urraient causer des dommages aux personnes 5 Brancher la pince rouge POSITIVE de l unit la borne POSITIVE position P sans prise de terre de la batterie Brancher pince noire N GATIVE au ch ssis du v hi...

Page 14: ...utilisation ult rieure NE touchez PAS aux bornes de la batterie car cela entra nerait un arc lectrique 7 Retirez la batterie sup rieure arri re en la soulevant vers le haut en la tournant et en la fa...

Page 15: ...rs m le double femelle simple sur le chargeur n 1 chargeur sup rieur 12 Assurez vous que le commutateur de ventilation de la batterie mont sur le double chargeur correspond au type de batterie install...

Page 16: ...eliez les goujons de la jauge pour voir si le chargeur fonctionne remplacez la jauge Remplacez le chargeur R glez la position 12 volts CAUSE POSSIBLE Les connexions rapides ne sont pas attach es ensem...

Page 17: ...E EN VERTU D UNE RUPTURE DE GARANTIE EXPRESSE OU TACITE D UNE N GLIGENCE D UNE RESPONSABILIT CIVILE D LICTUELLE AU SENS STRICT OU TOUTE AUTRE BASE JURIDIQUE Cette garantie s applique toute personne de...

Page 18: ......

Page 19: ......

Page 20: ...ual Model HT1224AGM Commercial Jump Starter This product can expose you to lead which is known to the State of California to cause birth defects or other reproductive harm and Vinyl Chloride Styrene a...

Reviews: