08/2016
23
Heater type
Power
Wall installation
Ceiling installation
Horizontal
Vertical
Horizontal
Inclined
IR 05008
2500 W
15
9
52
6
8
10
9
6
2
1
GB
2b. Installation, radiant heater S3
(Heater type IR 05008) with T-brackets
Step 1: Installing the T-brackts
• Install the S3 radiant heater using 2 T brackets at a separation of 400 mm while
observing the safety distances and safety instructions (see Appendix 2).
• Secure the T-bracket (1) with the silicone plate (2) below it on the fastening
surface with 2 screws each according to the following figure.
Step 2: Installing adapter claws on the T-brackets
• Push the adapter claws (6) into both T-brackets (1) mounted on the fastening
surface. Insert the M8x20/5 mm AF screws (8) into the holes. Insert the washer
(9) and tighten the M8/13 mm AF nuts (10).