CONNECTIONS – ELECTRICAL
35
EXTERNAL CONTROL DEVICE
An external control device, the Energy Management Unit, must be installed for this water heater to operate as
a variable power water heater and take advantage of special tariffs and rebates from
the consumer’s electricity
utility. An external Power Meter is also required to take advantage of excess power generated by a solar PV
system. The Energy Management Unit is installed remote from the water heater. The external Power Meter is
wired directly to the switchboard. The Energy Management Unit and Power Meter communicate with the
controller module on the water heater. Refer to the installation instructions provided with the Energy
Management Unit and external Power Meter for details of their installation.
The PowerStore water heater’s controller module is capable of communications using the power line
telecommunications (PLT) protocol. It is not necessary to hard wire to the water heater an Energy Management
Unit or Power Meter that is PLT capable and protocol compliant with the PowerStore water heater.
WIRING DIAGRAM
Top thermostat
– setting
80°C
Bottom thermostat
– setting
80°C.
Electrical Circuit for Twin Element Variable Power Water Heater
Robertshaw “ST” Thermostats