background image

The Answer in Power Protection

ups

 

320

Table of Contents

Starting the Unit

.............................................. 2

SOLA 320 UPS Features .................................... 3
Unit Identification .............................................. 4
Symbols, LEDs and Audible Beeps ..................... 5
Troubleshooting

.............................................. 6

Replacing the Fuse ............................................. 7
Replacing the Batteries ....................................... 8
Communication Port ......................................... 11
Specifications

............................................ 12

Warranty

............................................ 13

SOLA Offices

............................................ 16

Trademarks

Windows is a registered trademark of Microsoft Corporation.

All other brand and product names are trademarks or registered
trademarks of their respective holders

ii

Summary of Contents for 0320-0400A

Page 1: ...otection SOLA 320opman Copyright 1997 All rights reserved ups 320 Installation and Operation Manual Savetheseinstructions This manual contains important instructions that should be followed during installation and maintenance of the UPS ...

Page 2: ...rous voltage present at the unit s outlets This is true because the unit s battery supplies power even if the unit is not plugged into the wall outlet The unit contains dangerous voltages To reduce the risk of electric shock intall the SOLA 320 UPS in a temperature controlled and humidity controlled indoor area free of conductive contaminants The power supply cord is intended to serve as the disco...

Page 3: ...LEDs and Audible Beeps 5 Troubleshooting 6 Replacing the Fuse 7 Replacing the Batteries 8 Communication Port 11 Specifications 12 Warranty 13 SOLA Offices 16 Trademarks Windows is a registered trademark of Microsoft Corporation All other brand and product names are trademarks or registered trademarks of their respective holders ii ...

Page 4: ...line LED will come on The green line LED should remain on If not see the Troubleshooting section on page 6 4 Switch off the load equipment and plug it into the outlets on the back of the SOLA 320 UPS 5 Switch on the load equipment one piece at a time 6 The Telephone Network Surge Protection jacks will protect equipment phone fax modem or 10BASE T network connection that utilizes an RJ 11 or RJ 45 ...

Page 5: ... Play Installation If a dialog box appears during Windows 95 startup announcing that the program has found a SOLA 320 UPS you may follow the steps below for quick CheckUPS II installation When Windows 95 displays the New Hardware Found dialog box select the Driver from disk provided by hardware manufac turer option and click the OK button When the Install from Disk dialog box is displayed insert t...

Page 6: ...The Answer in Power Protection ups 320 ...

Page 7: ...nel LEDs and an audible alarm keep you aware of the unit s status Use the table below and the drawings on page 4 to familiarize yourself with the unit Model 0320 0400A 0320 0750A 0320 1000A VA Rating 400 750 1000 Input Voltage Range On Line 191 VAC 5 278 VAC 5 Input Line Cord provided 10 amp 3 flat pin Australian Male connector and a Female IEC 320 plug Output Voltage Regulation On Line and On Bat...

Page 8: ...etwork Surge Protection 2 Alarm Silence Button 6 Output Receptacles 3 On Off Button 7 Input Connector 4 DB9 Communication Port 8 Fuse 9 Circuit Breaker USEONLYWITHA250VFUSE 5 6 Back Panel 400VA 400 ups 320 Front Panel 400VA ups 320 Front Panel 750 1000VA Back Panel 750 1000VA 1 2 3 4 7 8 1 2 3 4 5 6 9 7 ...

Page 9: ... e s h i g h i n p u t p o w e r t o p r e v e n t t h e u n i t f r o m s w i t c h i n g t o b a t t e r y B A T T E R Y M O D E Y e l l o w T h e u n i t i s r u n n i n g o n b a t t e r y p o w e r O V E R L O A D R e d O u t p u t O v e r l o a d R e fe r t o T a b l e s 2 3 W A R N IN G R e d R e p la c e t h e b a t t e r y o r U P S F a u l t R e f e r to Ta b le s 2 3 N u m b e r o f B e...

Page 10: ...e n L IN E L E D o ff tw o b e e p s e v e r y f i v e s e c o n d s V e r y lo w b a tte r y v o lta g e P l u g t h e u n i t i n t o a w o r k i n g w a ll o u t l e t f o r a t le a s t 8 h o u r s t o a llo w the b a t t e r i e s t o c h a r g e T h e g r e e n L IN E L E D w ill s w i t c h o n w h e n p o w e r r e t u r n s I f a f t e r 8 h o u r s o f r e c h a r g i n g y e l l o w B A...

Page 11: ... below the fuse holder 3 400VA and 750U and 1000U Models The top of the fuse holder has a small notch Gently pry the fuse holder out of the unit 4 400VA Models and 750U and 1000U Models One spare fuse is provided in the fuse holder If the spare fuse has been used call SOLA s Worldwide Service to order a new fuse Push the spare fuse out of the holder Remove and discard the old fuse and put the new ...

Page 12: ...attery It must be the same type and rating of the original battery 2 Switch off and unplug the protected load equipment from the SOLA 320 UPS unit Turn off the SOLA 320 UPS Disconnect the line cord from the SOLA 320 UPS 3 On the bottom of the SOLA 320 UPS remove the Phillips screw at the top of the battery door and slide the door off ...

Page 13: ...arefully install the battery back into the SOLA 320 UPS 7 Slide the battery door back into place and secure with the Phillips screw removed in step 3 8 Reconnect the line cord to the SOLA 320 UPS unit and turn the unit on 9 Reconnect the load equipment 10 Switch on the protected load equipment one piece at a time 750 VA and 1000 VA Models 1 Phone SOLA s Worldwide Service to order a replace ment ba...

Page 14: ...4 Remove the two screws from the interior panel to gain access to the batteries 5 Pull the batteries out of the unit by using the flap attached to the batteries 6 Disconnect the cables from the used battery pack Dispose of the old batteries properly 7 Reconnect the cables to the new battery pack red to positive black to negative and slide them into the unit 8 Use the two screws removed in Step 4 t...

Page 15: ...s or specific information on SOLA interface kits call SOLA s Worldwide Service or your local SOLA dealer Banyan VINES IBM RS 6000 AIX IBM AS 400 special Lantastic v4 0 LAN Manager Server v2 0 Pinouts Pin1 Shutdown A 12 VDC signal held for 5 seconds on this pin while the unit is on battery shuts down the unit 120 seconds later The unit restarts after a 10 second delay when acceptable line power is ...

Page 16: ... EEC Noise RF Suppression Full time EMI RFI filtering Efficiency 90 on line Capacity VA Watts 400VA 250W 750VA 490W 1000VA 630W Frequency 50 60 Hz auto sensing 57 63 Hz 60 Hz 47 53 Hz 50 Hz 50 60 Hz 1 Hz on battery Typical Runtime minutes 400VA Full load 4 min Half load 15 min 750 1000VA Full load 5 min Half load 12 min Transfer Time 4 ms typical Telephone line surge suppression per Bellcore 1089 ...

Page 17: ... or other materials that corrode orcontaminate Air must be free to move around the unit Operating Temperature 32 104 F 0 40 C Humidity 5 95 RH non condensing Dimensions Height x Width x Length 400VA 6 x 4 x 14 25 inches 155 x 100 x 365 mm 750 1000VA 8 25 x 6 5 x 14 25 inches 207 x 163 x 365 mm Weight 400 VA 17 5 lbs 8 kg 750 VA 30 lbs 13 5 kg Fuse All other models Fuse See label on unit for fuse s...

Page 18: ...ship 3 Any modification made to the product other than those made by Sola or its authorised representative may cause the Warranty to be void 4 For units up to 3kVA that are installed as a portable device the Warranty covers repair or replacement of defective parts at the factory or other service locations as nominated by Sola Australia provided the unit has been returned by the user packed adequat...

Page 19: ...PS equipment These batteries have a finite life expectancy depending on a number of variables including rate of discharge depth of discharge operating temperature etc 7 Providing that the batteries are used within the limits as set out in Sola Operating Manuals they are guaranteed for one year from despatch date as per invoice 8 Sola reserves the right to charge for replacement batteries if within...

Page 20: ...The Answer in Power Protection ups 320 ...

Page 21: ...ginal packing container Damage resulting from shipment in a non original container will void this warranty For proper handling upon receipt at SOLA the R A Number must be clearly placed in several locations on the outside of the package SOLA will not be responsible for damage to returned goods that have not been properly packaged or damage exceeding normal wear and tear For Service in Australiacon...

Page 22: ...ay of off the shelf products for the fastest possible delivery In addition SOLA BEST field sales offices are conveniently located to provide prompt attention to customer needs Call SOLA BEST direct to find the closest authorised distributor SOLA BEST Offices SOLA Australia Ltd Best Power Best Power Technology Limited 13 Healey Road PO Box 2 BEST House Wykeham Industrial Estate Dandenong VIC 3175 N...

Page 23: ...The Answer in Power Protection ups 320 ...

Page 24: ...The Answer in Power Protection ups 320 400 750 front buck ...

Page 25: ...The Answer in Power Protection ups 320 network overload sola400a warning ...

Page 26: ...The Answer in Power Protection ups 320 ...

Page 27: ...The Answer in Power Protection ups 320 ...

Reviews: