Instruction Manual
INOXA SERIES
16
GB
B) JOB SAVING.
After having done the setting of one or more parameters, it is pos-
sible to memorize them in one of the available JOBS. It is possible
to memorize also working cycle such as: 2 or 4 Times cycle, timer,
pulsation, o electrode modality.
1.
Press the knob (7) for
about 2 sec.
2.
The display will show:
“MEM JOB”.
The LED JOB (9A) will flash.
3.
Select the JOB from 1 to
10 by turning the knob (7).
E.g. JOB n° 7
4.
Press again the knob (7)
for about 2 sec. to memorize
the JOB.
5.
The LED JOB (9A) will
stay ON.
6.
To exit the job modality
press the pushbutton (9)
until the LED (9A) turns
OFF.
HFP
series
7
Push > 2 sec
HFP
series
9A
7
Push > 2 sec
1.
Set the knob (7) on half
scale.
2.
Turn ON the machine
and press the pushbutton
TEST GAS (8) within 1-2
sec.
3.
On the display it will
appear the writing “REG
GAS” followed by “0”.
4.
With the knob (7) set the
percentage of the POST
GAS time reduction.
E.g. - 50%, the display will
show “- 5”.
5.
Turn clockwise to incre-
ase and counter-clockwise
to decrease.
A variation from 0 to +/- 90%
is possible.
6.
Press the pushbutton (8)
to confirm the setting.
HF
series
7
NOTE:
numbers shown below are referring to Fig. 1-2 chapter 6
COMMANDS DESCRIPTION to Page 4-5.
It is possible to modify the synergy value of the POST GAS time, to
adapt it to specific needs. For example, in a spot welding cycle the
time results too much long and it is needed to be shortened.
8.14 POST GAS TIME SETTING
(Only on INOXA HF series)
8
HF
series
7
8