229
31. CHANGING THE SETTINGS
Communication Setup
Select “Comms setup” in Config mode
Items set and options (*: Factory setting)
The setting effective when selecting "T types"
The setting effective when selecting "S types"
• The followings are communication formats compatible with the CX.
Depending on the communication format used, select T type/S type.
Output format and command operations: "Communication manual"
Baud rate
1200bps, 2400bps, 4800bps, 9600bps*,
19200bps, 38400bps
Data bits
8bit*, 7bit
Parity
None*, Odd, Even
Stop bit
1bit*, 2bit
ACK/NAK
Yes, No*
CR, LF
Yes, No*
ACK mode
Standard*, Omitted
Check sum
Yes, No*
T type
GTS (Obs / Coord), SSS (Obs / Coord)
S type
SDR33, SDR2X
Baud rate
Data bits
Parity
Stop bit
Check sum
:
9600bps
: 8bit
: None
: 1bit
: No
ACK/NAK
: No
CR, LF
ACK mode
:
No
: Standard